Installation Guide for the 9 dBi Omni-directional Antenna ANT2409
2-4 Installing the 9 dBi Omni-directional Antenna
3. Connect the grounding cable (not included) from the lightning arrestor to the ground of the
building.
Grounding cable: The grounding cable must be equivalent or better than: AWG 10, UL 1015,
Stranded, 600 V, 105
o
C, green or green/yellow insulation, 2 clip of 5.5 mm inner diameter
cramped at both ends, cable no longer than 5 meters.
WARNING: the lightning arrestor and appropriate ground cable must be used for outdoor
installation. NETGEAR does not assume any responsibility in case of hazard resulting of
non-compliance with these instructions.
4. Screw the N/SMA Reverse Adapter on the lightning arrestor (clockwise) on the second RF
port. Connect a NETGEAR cable model ACC-10314-01, 02, 03, 04 or 05 (sold separately) to
the adapter.
5. Locate the primary detachable antenna on the wireless access point. Remove the antenna and
connect the other end of the NETGEAR cable ACC-10314-01, 02, 03, 04 or 05 to this port.
NOTE: On access points with two antennas, if you are only replacing one antenna, be sure to
replace the primary antenna and do not remove the secondary antenna.
6. After attaching your new 9 dBi antenna(s), reconnect your wireless device to the network and
turn them on.