Netgear Switch M4100-12G-POE+ Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking Netgear Switch M4100-12G-POE+. Netgear Switch M4100-12G-POE+ User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 768
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
350 East Plumeria Drive
San Jose, CA 95134
USA
February 2013
202-11166-02
1.0
ProSafe Managed Switch
Command Line Interface (CLI)
User Manual
10.0.1
M7100-24X
M4100-24G-POE+
M4100-26G
M4100-26-POE
M4100-26G-POE
M4100-50G
M4100-50-POE
M4100-50G-POE+
M4100-12GF
M4100-12G-POE+
M4100-D12G
M4100-D10-POE
M4100-D12G-POE+
Przeglądanie stron 0
1 2 3 4 5 6 ... 767 768

Podsumowanie treści

Strona 1 - ProSafe Managed Switch

350 East Plumeria DriveSan Jose, CA 95134USAFebruary 2013202-11166-021.0ProSafe Managed SwitchCommand Line Interface (CLI) User Manual10.0.1M7100-24XM

Strona 2 - Revision History

Using the Command-Line Interface10ProSafe M4100 and M7100 Managed Switches The parameters for a command might include mandatory values, optional value

Strona 3 - Contents

Switching Commands100ProSafe M4100 and M7100 Managed Switches no storm-control multicast levelThis command sets the multicast storm recovery threshold

Strona 4 - Chapter 4 Routing Commands

Switching Commands101 ProSafe M4100 and M7100 Managed Switchesno storm-control unicastThis command disables unicast storm recovery mode for an interfa

Strona 5 - Chapter 10 Utility Commands

Switching Commands102ProSafe M4100 and M7100 Managed Switches no storm-control unicast rateThis command sets the unicast storm recovery threshold to t

Strona 6 - Chapter 14 Command List

Switching Commands103 ProSafe M4100 and M7100 Managed Switchesno storm-control unicast levelThis command sets the unicast storm recovery threshold to

Strona 7

Switching Commands104ProSafe M4100 and M7100 Managed Switches Use the all keyword to display the per-port configuration parameters for all interfaces,

Strona 8 - Licensing and Command Support

Switching Commands105 ProSafe M4100 and M7100 Managed Switchesno flowcontrol Format no flowcontrolMode• Global Config• Interface Configshow flowcontro

Strona 9 - Command Conventions

Switching Commands106ProSafe M4100 and M7100 Managed Switches A port-channel (LAG) interface can be either static or dynamic, but not both. All member

Strona 10 - Common Parameter Values

Switching Commands107 ProSafe M4100 and M7100 Managed Switcheslacp admin keyUse this command to configure the administrative value of the key for the

Strona 11 - Slot/Port Naming Convention

Switching Commands108ProSafe M4100 and M7100 Managed Switches lacp actor admin keyUse this command to configure the administrative value of the LACP a

Strona 12 - Command Modes

Switching Commands109 ProSafe M4100 and M7100 Managed SwitchesNote: This command is only applicable to physical interfaces.no lacp actor admin state

Strona 13 - Table 5. CLI Command Modes

Using the Command-Line Interface11 ProSafe M4100 and M7100 Managed SwitchesSlot/Port Naming ConventionManaged switch software references physical enti

Strona 14

Switching Commands110ProSafe M4100 and M7100 Managed Switches no lacp actor port priorityUse this command to configure the default priority value assi

Strona 15

Switching Commands111 ProSafe M4100 and M7100 Managed Switchesno lacp partner admin keyUse this command to configure the administrative value of the K

Strona 16 - CLI Error Messages

Switching Commands112ProSafe M4100 and M7100 Managed Switches lacp partner admin state passiveUse this command to set the LACP partner admin state to

Strona 17 - Using CLI Help

Switching Commands113 ProSafe M4100 and M7100 Managed SwitchesNote: This command is only applicable to physical interfaces.no lacp partner port prior

Strona 18 - Accessing the CLI

Switching Commands114ProSafe M4100 and M7100 Managed Switches Note: This command is applicable only to physical interfaces.no lacp partner system pri

Strona 19

Switching Commands115 ProSafe M4100 and M7100 Managed Switchesno port-channel staticThis command sets the static mode on a particular port-channel (LA

Strona 20

Switching Commands116ProSafe M4100 and M7100 Managed Switches no port lacptimeoutThis command sets the timeout back to its default value on a physical

Strona 21 - Port Configuration Commands

Switching Commands117 ProSafe M4100 and M7100 Managed Switchesport-channel linktrapThis command enables link trap notifications for the port-channel (

Strona 22

1234567<slot/port>| allSwitching Commands118ProSafe M4100 and M7100 Managed Switches no port-channel load-balanceThis command reverts to the def

Strona 23

Switching Commands119 ProSafe M4100 and M7100 Managed Switchesno port-channel system priorityUse this command to configure the default port-channel sy

Strona 24

Using the Command-Line Interface12ProSafe M4100 and M7100 Managed Switches Note: In the CLI, loopback and tunnel interfaces do not use the slot/port

Strona 25

Switching Commands120ProSafe M4100 and M7100 Managed Switches show port-channel briefThis command displays the static capability of all port-channel (

Strona 26

Switching Commands121 ProSafe M4100 and M7100 Managed Switchesshow port-channel system priorityUse this command to display the port-channel system pri

Strona 27 - Loopback Interface Commands

Switching Commands122ProSafe M4100 and M7100 Managed Switches no monitor sessionUse this command without optional parameters to remove the monitor ses

Strona 28

Switching Commands123 ProSafe M4100 and M7100 Managed SwitchesStatic MAC FilteringThe commands in this section describe how to configure static MAC fi

Strona 29

Switching Commands124ProSafe M4100 and M7100 Managed Switches no macfilter This command removes all filtering restrictions and the static MAC filter e

Strona 30

Switching Commands125 ProSafe M4100 and M7100 Managed Switches6-byte hexadecimal number in the format of b1:b2:b3:b4:b5:b6. The <vlanid> paramet

Strona 31

Switching Commands126ProSafe M4100 and M7100 Managed Switches 6-byte hexadecimal number in the format of b1:b2:b3:b4:b5:b6. The <vlanid> paramet

Strona 32

Mac AddressTypeDescriptionInterfacesSwitching Commands127 ProSafe M4100 and M7100 Managed SwitchesDHCP L2 Relay Agent CommandsYou can enable the switc

Strona 33

Switching Commands128ProSafe M4100 and M7100 Managed Switches Separate non-consecutive IDs with a comma (,), and do not insert spaces or zeros in betw

Strona 34

Switching Commands129 ProSafe M4100 and M7100 Managed Switchesno dhcp l2relay vlanUse this command to disable the DHCP L2 Relay agent for a set of VLA

Strona 35

Using the Command-Line Interface13 ProSafe M4100 and M7100 Managed Switchescommands. You can execute the User EXEC mode commands in the Privileged EXE

Strona 36

Switching Commands130ProSafe M4100 and M7100 Managed Switches show dhcp l2relay interfaceUse this command to display DHCP L2 relay configuration speci

Strona 37

Switching Commands131 ProSafe M4100 and M7100 Managed Switches5 Enabled Enabled --NULL—6 Enabled

Strona 38

Switching Commands132ProSafe M4100 and M7100 Managed Switches show dhcp client vendor-id-optionUse this command to display the configured administrati

Strona 39

Switching Commands133 ProSafe M4100 and M7100 Managed Switchesno ip dhcp snooping vlanUse this command to disable DHCP Snooping on VLANs.Format no ip

Strona 40

Switching Commands134ProSafe M4100 and M7100 Managed Switches no ip dhcp snooping database write-delayUse this command to set the write delay value to

Strona 41

Switching Commands135 ProSafe M4100 and M7100 Managed Switchesno ip dhcp snooping limitUse this command to set the rate at which the DHCP Snooping mes

Strona 42

Switching Commands136ProSafe M4100 and M7100 Managed Switches ip verify sourceUse this command to configure the IPSG source ID attribute to filter the

Strona 43

Switching Commands137 ProSafe M4100 and M7100 Managed Switches0/1 Yes No 0/2 No Yes 0/3 No

Strona 44

Switching Commands138ProSafe M4100 and M7100 Managed Switches show ip dhcp snooping databaseUse this command to display the DHCP Snooping configuratio

Strona 45

Switching Commands139 ProSafe M4100 and M7100 Managed SwitchesExample: The following shows example CLI display output for the command.(switch) #show i

Strona 46

Using the Command-Line Interface14ProSafe M4100 and M7100 Managed Switches Table 6 explains how to enter or exit each mode.Router OSPF ConfigSwitch

Strona 47 - VLAN Commands

Switching Commands140ProSafe M4100 and M7100 Managed Switches show ip verify sourceUse this command to display the IPSG configurations on all ports.Fo

Strona 48

Switching Commands141 ProSafe M4100 and M7100 Managed SwitchesThe following shows sample CLI display output for the command.(switch) #show ip source b

Strona 49

Switching Commands142ProSafe M4100 and M7100 Managed Switches ip arp inspection validateUse this command to enable additional validation checks like s

Strona 50

Switching Commands143 ProSafe M4100 and M7100 Managed Switchesno ip arp inspection trustUse this command to configure an interface as untrusted for Dy

Strona 51

Switching Commands144ProSafe M4100 and M7100 Managed Switches no ip arp inspection filterUse this command to unconfigure the ARP ACL used to filter in

Strona 52

Switching Commands145 ProSafe M4100 and M7100 Managed Switchesthe given VLAN list. The global configuration includes the source mac validation, destin

Strona 53

Switching Commands146ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command show ip arp insp

Strona 54

Switching Commands147 ProSafe M4100 and M7100 Managed Switchescommand displays the values for that interface whether the interface is enabled for DAI

Strona 55

Switching Commands148ProSafe M4100 and M7100 Managed Switches IGMP Snooping Configuration CommandsThis section describes the commands you use to confi

Strona 56

Format no set igmp <vlanid>ModeSwitching Commands149 ProSafe M4100 and M7100 Managed Switchesset igmp interfacemode This command enables IGMP Sn

Strona 57

Using the Command-Line Interface15 ProSafe M4100 and M7100 Managed SwitchesPolicy-Map ConfigFrom the Global Config mode, enter policy-map <name&g

Strona 58

Switching Commands150ProSafe M4100 and M7100 Managed Switches no set igmp fast-leaveThis command disables IGMP Snooping fast-leave admin mode on a sel

Strona 59

Switching Commands151 ProSafe M4100 and M7100 Managed Switchesparticular group in that interface. This value must be less than the IGMP Query Interval

Strona 60 - Double VLAN Commands

Switching Commands152ProSafe M4100 and M7100 Managed Switches no set igmp mcrtrexpiretimeThis command sets the Multicast Router Present Expiration tim

Strona 61

Switching Commands153 ProSafe M4100 and M7100 Managed Switchesset igmp report-suppressionUse this command to suppress the IGMP reports on a given VLAN

Strona 62

Switching Commands154ProSafe M4100 and M7100 Managed Switches mac address-table multicast forbidden-unregistered vlanUse this command to forbid forwar

Strona 63 - Voice VLAN Commands

Switching Commands155 ProSafe M4100 and M7100 Managed Switchesshow igmpsnoopingThis command displays IGMP Snooping information. Configured information

Strona 64

Switching Commands156ProSafe M4100 and M7100 Managed Switches show igmpsnooping mrouter interfaceThis command displays information about statically co

Strona 65 - Protected Ports Commands

Switching Commands157 ProSafe M4100 and M7100 Managed Switchesshow mac-address-table igmpsnoopingThis command displays the IGMP Snooping entries in th

Strona 66

Switching Commands158ProSafe M4100 and M7100 Managed Switches set igmp querierUse this command to enable IGMP Snooping Querier on the system, using Gl

Strona 67

Switching Commands159 ProSafe M4100 and M7100 Managed Switchesno set igmp querier query-intervalUse this command to set the IGMP Querier Query Interva

Strona 68 - Private VLAN

Using the Command-Line Interface16ProSafe M4100 and M7100 Managed Switches Command Completion and AbbreviationCommand completion finishes spelling the

Strona 69

Switching Commands160ProSafe M4100 and M7100 Managed Switches than the Snooping Querier’s address, it stops sending periodic queries. If the Snooping

Strona 70

Switching Commands161 ProSafe M4100 and M7100 Managed SwitchesWhen you specify a value for <vlanid>, the following additional information appear

Strona 71 - GARP Commands

Switching Commands162ProSafe M4100 and M7100 Managed Switches interface. MLD Snooping functionality is re-enabled if you disable routing or remove por

Strona 72

Switching Commands163 ProSafe M4100 and M7100 Managed Switchesset mld fast-leaveUse this command to enable MLD Snooping fast-leave admin mode on a sel

Strona 73 - GVRP Commands

Switching Commands164ProSafe M4100 and M7100 Managed Switches no set groupmembership-intervalUse this command to set the MLDv2 Group Membership Interv

Strona 74

Switching Commands165 ProSafe M4100 and M7100 Managed Switchesinterfaces with multicast routers attached. The range is 0–3600 seconds. A value of 0 in

Strona 75 - GMRP Commands

Switching Commands166ProSafe M4100 and M7100 Managed Switches no set mld mrouter interfaceUse this command to disable the status of the interface as a

Strona 76

Switching Commands167 ProSafe M4100 and M7100 Managed SwitchesWhen you specify a value for vlanid, the following information appears.VLAN Admin Modesh

Strona 77

VLAN IDMAC AddressTypeDescriptionInterfacesSwitching Commands168ProSafe M4100 and M7100 Managed Switches MLD Snooping Querier Commands In an IPv6 envi

Strona 78

Switching Commands169 ProSafe M4100 and M7100 Managed Switchesno set mld querier Use this command to disable MLD Snooping Querier on the system. Use t

Strona 79

Using the Command-Line Interface17 ProSafe M4100 and M7100 Managed SwitchesCLI Line-Editing ConventionsTable 8 describes the key combinations you can

Strona 80

Switching Commands170ProSafe M4100 and M7100 Managed Switches set mld querier election participateUse this command to enable the Snooping Querier to p

Strona 81

Switching Commands171 ProSafe M4100 and M7100 Managed SwitchesWhen you specify a value for vlanid, the following information appears.When the optional

Strona 82

Switching Commands172ProSafe M4100 and M7100 Managed Switches port-securityThis command enables port locking at the system level (Global Config) or po

Strona 83

Switching Commands173 ProSafe M4100 and M7100 Managed Switchesno port-security max-staticThis command sets maximum number of statically locked MAC add

Strona 84

Switching Commands174ProSafe M4100 and M7100 Managed Switches no port-security mac-address stickyThe no form removes the sticky mode. The sticky MAC a

Strona 85

Switching Commands175 ProSafe M4100 and M7100 Managed Switchesshow port-security staticThis command displays the statically locked MAC addresses for p

Strona 86

Switching Commands176ProSafe M4100 and M7100 Managed Switches lldp receiveUse this command to enable the LLDP receive capability. DefaultFormat lldp r

Strona 87

Switching Commands177 ProSafe M4100 and M7100 Managed SwitchesUse port-desc to transmit the port description TLV. To configure the port description, s

Strona 88

Switching Commands178ProSafe M4100 and M7100 Managed Switches no lldp notificationUse this command to disable notifications.DefaultFormat no lldp noti

Strona 89

Switching Commands179 ProSafe M4100 and M7100 Managed Switchesshow lldpUse this command to display a summary of the current LLDP configuration.Format

Strona 90

Using the Command-Line Interface18ProSafe M4100 and M7100 Managed Switches enable Enter into user privilege mode.help

Strona 91 - 802.1X Supplicant Commands

Switching Commands180ProSafe M4100 and M7100 Managed Switches show lldp statisticsUse this command to display the current LLDP traffic and remote tabl

Strona 92

Switching Commands181 ProSafe M4100 and M7100 Managed Switchesshow lldp remote-deviceUse this command to display summary information about remote devi

Strona 93

Switching Commands182ProSafe M4100 and M7100 Managed Switches show lldp remote-device detailUse this command to display detailed information about rem

Strona 94 - Storm-Control Commands

Switching Commands183 ProSafe M4100 and M7100 Managed SwitchesPort ID: 00:FC:E3:90:01:11System Name:System Description:Port Description:System Capabil

Strona 95

Switching Commands184ProSafe M4100 and M7100 Managed Switches LLDP-MED CommandsLink Layer Discovery Protocol - Media Endpoint Discovery (LLDP-MED) (AN

Strona 96

Switching Commands185 ProSafe M4100 and M7100 Managed Switchesno ldp med confignotificationUse this command to disable notifications.Format no lldp me

Strona 97

Switching Commands186ProSafe M4100 and M7100 Managed Switches lldp med allFormat lldp med allModeUse this command to configure LLDP-MED on all the por

Strona 98

Switching Commands187 ProSafe M4100 and M7100 Managed Switcheslldp med transmit-tlv allUse this command to specify which optional Type Length Values (

Strona 99

Switching Commands188ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command.(switch) #show l

Strona 100 - Switching Commands

Switching Commands189 ProSafe M4100 and M7100 Managed Switches 0/13 Down Disabled Disabled Disabled 0,1 0/14 Down Disabled Disa

Strona 101

1922. Switching CommandsThis chapter describes the switching commands available in the managed switch CLI. This chapter contains the following secti

Strona 102

Switching Commands190ProSafe M4100 and M7100 Managed Switches (Switch) #show lldp med local-device detail 0/8LLDP MED Local Device DetailInterface: 0/

Strona 103

Switching Commands191 ProSafe M4100 and M7100 Managed Switchesshow lldp med remote-deviceThis command displays summary information about remote device

Strona 104 - Flow Control Commands

Switching Commands192ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command.(Switch) #show l

Strona 105

Switching Commands193 ProSafe M4100 and M7100 Managed SwitchesLLDP MED Remote Device DetailLocal Interface: 0/8Remote Identifier: 18CapabilitiesMED Ca

Strona 106

Switching Commands194ProSafe M4100 and M7100 Managed Switches This section describes the commands you use to configure Denial of Service (DoS) Control

Strona 107

Switching Commands195 ProSafe M4100 and M7100 Managed Switchesdos-control sipdipThis command enables Source IP address = Destination IP address (SIP=D

Strona 108

Switching Commands196ProSafe M4100 and M7100 Managed Switches dos-control tcpfragThis command enables TCP Fragment Denial of Service protection. If th

Strona 109

Switching Commands197 ProSafe M4100 and M7100 Managed SwitchesNote: Some applications mirror source and destination L4 ports - RIP for example uses 5

Strona 110

Switching Commands198ProSafe M4100 and M7100 Managed Switches this type of attack. If packets ingress with SMAC=DMAC, the packets will be dropped if t

Strona 111

Switching Commands199 ProSafe M4100 and M7100 Managed Switchesno dos-control udpportThis command disables UDP L4 source = destination port number (Sou

Strona 112

2ProSafe M4100 and M7100 Managed Switches SupportThank you for selecting NETGEAR products. After installing your device, locate the serial number on t

Strona 113

Switching Commands20ProSafe M4100 and M7100 Managed Switches • Port Security Commands • LLDP (802.1AB) Commands • LLDP-MED Commands •

Strona 114

Switching Commands200ProSafe M4100 and M7100 Managed Switches dos-control tcpsynThis command enables TCP SYN and L4 source = 0-1023 Denial of Service

Strona 115

Switching Commands201 ProSafe M4100 and M7100 Managed Switchesno dos-control tcpfinurgpshThis command sets disables TCP FIN and URG and PSH and SEQ=0

Strona 116

Switching Commands202ProSafe M4100 and M7100 Managed Switches no dos-control icmpv6This command disables Maximum ICMP Packet Size Denial of Service pr

Strona 117

Switching Commands203 ProSafe M4100 and M7100 Managed SwitchesMAC Database CommandsThis section describes the commands you use to configure and view i

Strona 118

Switching Commands204ProSafe M4100 and M7100 Managed Switches no bridge aging-timeThis command sets the forwarding database address aging timeout to t

Strona 119

Switching Commands205 ProSafe M4100 and M7100 Managed Switchesshow mac-address-table statsThis command displays the Multicast Forwarding Database (MFD

Strona 120

Switching Commands206ProSafe M4100 and M7100 Managed Switches isdp timerThis command sets the period of time between sending new ISDP packets. The ran

Strona 121 - Port Mirroring

Switching Commands207 ProSafe M4100 and M7100 Managed Switchesclear isdp countersThis command clears ISDP counters.Format clear isdp countersModeclear

Strona 122

Switching Commands208ProSafe M4100 and M7100 Managed Switches show isdp interfaceThis command displays ISDP settings for the specified interface.Forma

Strona 123 - Static MAC Filtering

Switching Commands209 ProSafe M4100 and M7100 Managed SwitchesExample: The following shows example CLI display output for the command.(Switch) #show i

Strona 124

Switching Commands21 ProSafe M4100 and M7100 Managed SwitchesPort Configuration CommandsThis section describes the commands you use to view and config

Strona 125

Switching Commands210ProSafe M4100 and M7100 Managed Switches debug isdp packetThis command enables tracing of ISDP packets processed by the switch. I

Strona 126

Switching Commands211 ProSafe M4100 and M7100 Managed Switchesdropped frames, while allowing traffic that has greater loss tolerance to continue to fl

Strona 127 - DHCP L2 Relay Agent Commands

Switching Commands212ProSafe M4100 and M7100 Managed Switches VLAN tagging must be enabled to carry the 802.1p value through the network. The number o

Strona 128

21333. Multicast VLAN Registration (MVR)This chapter contains the following sections:• About MVR • MVR Commands

Strona 129

Multicast VLAN Registration (MVR)214ProSafe M4100 and M7100 Managed Switches About MVRInternet Group Management Protocol (IGMP) Layer 3 is widely used

Strona 130

Multicast VLAN Registration (MVR)215 ProSafe M4100 and M7100 Managed Switchesno mvr groupThis command removes the MVR membership group. mvr mode This

Strona 131 - DHCP Client Commands

Multicast VLAN Registration (MVR)216ProSafe M4100 and M7100 Managed Switches mvr vlanThis command sets the MVR multicast VLAN. no mvr vlanThis command

Strona 132

Multicast VLAN Registration (MVR)217 ProSafe M4100 and M7100 Managed Switchesmvr typeThis command sets the MVR port type. When a port is set as source

Strona 133

Multicast VLAN Registration (MVR)218ProSafe M4100 and M7100 Managed Switches The following table explains the output parameters.Example:(Switch)#show

Strona 134

Multicast VLAN Registration (MVR)219 ProSafe M4100 and M7100 Managed Switches(switch)#show mvr members 224.1.1.1MVR Group IP Status

Strona 135

Switching Commands22ProSafe M4100 and M7100 Managed Switches no auto-negotiateThis command disables automatic negotiation on a port.Note: Automatic s

Strona 136

Multicast VLAN Registration (MVR)220ProSafe M4100 and M7100 Managed Switches show mvr trafficThis command displays global MVR statistics.The following

Strona 137

22144. Routing CommandsThis chapter describes the routing commands available in the 7000 series CLI.Note: Some commands described in this chapter r

Strona 138

Routing Commands222ProSafe M4100 and M7100 Managed Switches Address Resolution Protocol (ARP) CommandsThis section describes the commands you use to c

Strona 139

Routing Commands223 ProSafe M4100 and M7100 Managed Switchesip proxy-arpThis command enables proxy ARP on a router interface. Without proxy ARP, a dev

Strona 140

Routing Commands224ProSafe M4100 and M7100 Managed Switches no arp dynamicrenewThis command prevents dynamic ARP entries from renewing when they age o

Strona 141

Routing Commands225 ProSafe M4100 and M7100 Managed Switchesno arp retriesThis command configures the default ARP count of maximum request for retries

Strona 142

Routing Commands226ProSafe M4100 and M7100 Managed Switches show arpThis command displays the Address Resolution Protocol (ARP) cache. The displayed r

Strona 143

Age Time (seconds)Response Time (seconds)RetriesCache SizeDynamic Renew ModeTotal Entry Count Current / PeakStatic Entry Count Current / MaxRouting Co

Strona 144

Routing Commands228ProSafe M4100 and M7100 Managed Switches no routing This command disables routing for an interface. You can view the current value

Strona 145

Routing Commands229 ProSafe M4100 and M7100 Managed Switchesno ip addressThis command deletes an IP address from an interface. The value for <ipadd

Strona 146

Switching Commands23 ProSafe M4100 and M7100 Managed Switchesno mtu This command sets the default MTU size (in bytes) for the interface. Format no mtu

Strona 147

Routing Commands230ProSafe M4100 and M7100 Managed Switches no ip default-gatewayUse this command to remove the default gateway address from the confi

Strona 148

Routing Commands231 ProSafe M4100 and M7100 Managed Switchesip routeThis command configures a static route. The <ipaddr> parameter is a valid

Strona 149

Routing Commands232ProSafe M4100 and M7100 Managed Switches ip route defaultThis command configures the default route. The value for <nexthopip>

Strona 150

Routing Commands233 ProSafe M4100 and M7100 Managed Switchesip netdirbcast This command enables the forwarding of network-directed broadcasts. When en

Strona 151

Routing Commands234ProSafe M4100 and M7100 Managed Switches no ip mtuThis command resets the ip mtu to the default value.Format no ip mtu <mtu>M

Strona 152

Routing Commands235 ProSafe M4100 and M7100 Managed Switchesshow ip briefThis command displays all the summary information of the IP, including the IC

Strona 153

Routing Interface StatusPrimary IP AddressSecondary IP AddressMethodRouting ModeAdministrative ModeForward Net Directed BroadcastsProxy ARPLocal Proxy

Strona 154

Routing Commands237 ProSafe M4100 and M7100 Managed SwitchesLink Speed Data Rate... InactiveMAC address...

Strona 155

Routing Commands238ProSafe M4100 and M7100 Managed Switches Maximum Paths The maximum number of next hops in an OSPF routeRouting for NetworksThe addr

Strona 156

Routing Commands239 ProSafe M4100 and M7100 Managed Switchesshow ip route This command displays the routing table. The <ip-address> specifies th

Strona 157

Switching Commands24ProSafe M4100 and M7100 Managed Switches no shutdown allThis command enables all ports.Format no shutdown allModespeed This comman

Strona 158

Routing Commands240ProSafe M4100 and M7100 Managed Switches To administratively control the traffic destined to a particular network and prevent it fr

Strona 159

Routing Commands241 ProSafe M4100 and M7100 Managed SwitchesECMP Group 1 with 2 next hops (used by 1 route) 172.20.33.100 on interface 2/33 172.20.3

Strona 160

Routing Commands242ProSafe M4100 and M7100 Managed Switches The following shows example CLI display output for the command.(router) #show ip route sum

Strona 161 - MLD Snooping Commands

Routing Commands243 ProSafe M4100 and M7100 Managed SwitchesTotal routes... 1032Best Routes (High)...

Strona 162

Routing Commands244ProSafe M4100 and M7100 Managed Switches show ip statsThis command displays IP statistical information. Refer to RFC 1213 for more

Strona 163

Routing Commands245 ProSafe M4100 and M7100 Managed Switchesip irdp This command enables Router Discovery on an interface. DefaultFormat ip irdp Moden

Strona 164

Routing Commands246ProSafe M4100 and M7100 Managed Switches no ip irdp holdtime This command configures the default value, in seconds, of the holdtime

Strona 165 - vlanid 0-3600

Routing Commands247 ProSafe M4100 and M7100 Managed Switchesip irdp preference This command configures the preferability of the address as a default r

Strona 166

Routing Commands248ProSafe M4100 and M7100 Managed Switches Virtual LAN Routing CommandsThis section describes the commands you use to view and config

Strona 167

Routing Commands249 ProSafe M4100 and M7100 Managed SwitchesVirtual Router Redundancy Protocol CommandsThis section describes the commands you use to

Strona 168

Switching Commands25 ProSafe M4100 and M7100 Managed Switchesshow port advertiseUse this command to display the local administrative link advertisemen

Strona 169

Routing Commands250ProSafe M4100 and M7100 Managed Switches ip vrrp modeThis command enables the virtual router configured on the specified interface.

Strona 170

Routing Commands251 ProSafe M4100 and M7100 Managed Switchesrequired when authorization type is simple text apssword. The parameter <vrid> is th

Strona 171 - Port Security Commands

Routing Commands252ProSafe M4100 and M7100 Managed Switches another router in the group higher than the master’s priority, the router will take over a

Strona 172

Routing Commands253 ProSafe M4100 and M7100 Managed Switchesdecrement) for each downed interface. The default priority decrement is changed using the

Strona 173

Routing Commands254ProSafe M4100 and M7100 Managed Switches ip vrrp <vrid> accept-modeThis command is used to allow a router to respond to ICMP

Strona 174

UptimeProtocolState Transitioned to Master Advertisement ReceivedAdvertisement Interval Errors Authentication FailureIP TTL errorsZero Priority Packet

Strona 175 - LLDP (802.1AB) Commands

Admin ModeRouter Checksum ErrorsRouter Version ErrorsRouter VRID ErrorsRouting Commands256ProSafe M4100 and M7100 Managed Switches show ip vrrp interf

Strona 176

Routing Commands257 ProSafe M4100 and M7100 Managed SwitchesAdvertisement Interval (secs)... 1Pre-empt Mode...

Strona 177

Routing Commands258ProSafe M4100 and M7100 Managed Switches no bootpdhcprelay cidoptmodeThis command disables the circuit ID option mode for BootP/DHC

Strona 178

Routing Commands259 ProSafe M4100 and M7100 Managed Switchesshow bootpdhcprelayThis command displays the BootP/DHCP Relay information.Format show boot

Strona 179

InterfaceType• Mirror - this port is a monitoring port. For more information, see Port Mirroring on page 121.• PC Mbr- this port is a member of a por

Strona 180 - {<slot/port>

Routing Commands260ProSafe M4100 and M7100 Managed Switches The ip helper-address command forwards specific UDP broadcast from one interface to anothe

Strona 181

Routing Commands261 ProSafe M4100 and M7100 Managed Switchesip helper-addressUse this command to add a unicast helper address to the list of helper ad

Strona 182

Routing Commands262ProSafe M4100 and M7100 Managed Switches The following shows example CLI display output for the command.(switch) #show ip helper-ad

Strona 183

Routing Commands263 ProSafe M4100 and M7100 Managed SwitchesOpen Shortest Path First (OSPF) CommandsThis section describes the commands you use to vie

Strona 184 - LLDP-MED Commands

Routing Commands264ProSafe M4100 and M7100 Managed Switches no network area (OSPF)Use this command to disable the OSPFv2 on an interface if the IP add

Strona 185

Routing Commands265 ProSafe M4100 and M7100 Managed Switchesno 1583compatibilityThis command disables OSPF 1583 compatibility. Format no 1583compatibi

Strona 186

Routing Commands266ProSafe M4100 and M7100 Managed Switches no area nssa default-info-originate (OSPF)This command disables the default route advertis

Strona 187

Routing Commands267 ProSafe M4100 and M7100 Managed Switchesof candidate causes the router to participate in the translator election process when it a

Strona 188

Routing Commands268ProSafe M4100 and M7100 Managed Switches no area rangeThe no form of this command deletes a specified area range or reverts an opti

Strona 189

Routing Commands269 ProSafe M4100 and M7100 Managed Switchesno area stubThis command deletes a stub area for the specified area ID.Format no area <

Strona 190

Switching Commands27 ProSafe M4100 and M7100 Managed Switchesshow port description This command displays the port description for every port.Format sh

Strona 191

Routing Commands270ProSafe M4100 and M7100 Managed Switches composed of standard displayable, non-control keystrokes from a Standard 101/102-key keybo

Strona 192

Routing Commands271 ProSafe M4100 and M7100 Managed Switchesarea virtual-link hello-interval (OSPF)This command configures the hello interval for the

Strona 193 - Denial of Service Commands

Routing Commands272ProSafe M4100 and M7100 Managed Switches area virtual-link transmit-delay (OSPF)This command configures the transmit delay for the

Strona 194 - • TCP SYN:

Routing Commands273 ProSafe M4100 and M7100 Managed SwitchesbandwidthBy default, OSPF computes the link cost of an interface as the ratio of the refer

Strona 195

Routing Commands274ProSafe M4100 and M7100 Managed Switches clear ip ospf configurationUse this command to reset the OSPF configuration to factory def

Strona 196

Routing Commands275 ProSafe M4100 and M7100 Managed Switchesdefault-information originate (OSPF)This command is used to control the advertisement of d

Strona 197

Routing Commands276ProSafe M4100 and M7100 Managed Switches no distance ospf This command sets the default route preference value of OSPF routes in th

Strona 198

Routing Commands277 ProSafe M4100 and M7100 Managed Switchesexternal-lsdb-limit (OSPF)This command configures the external LSDB limit for OSPF. If the

Strona 199

Routing Commands278ProSafe M4100 and M7100 Managed Switches authentication key must be 8 bytes or less if the authentication type is simple. If the ty

Strona 200

Routing Commands279 ProSafe M4100 and M7100 Managed Switchesno ip ospf database-filter all outUse this command in Interface Configuration mode to enab

Strona 201

Switching Commands28ProSafe M4100 and M7100 Managed Switches interface loopbackUse this command to enter the Interface Config mode for a loopback inte

Strona 202

Routing Commands280ProSafe M4100 and M7100 Managed Switches no ip ospf hello-intervalThis command sets the default OSPF hello interval for the specifi

Strona 203 - MAC Database Commands

Routing Commands281 ProSafe M4100 and M7100 Managed Switchesno ip ospf priority This command sets the default OSPF priority for the specified router i

Strona 204

Routing Commands282ProSafe M4100 and M7100 Managed Switches ip ospf mtu-ignoreThis command disables OSPF maximum transmission unit (MTU) mismatch dete

Strona 205 - ISDP Commands

Routing Commands283 ProSafe M4100 and M7100 Managed Switchesno redistribute This command configures OSPF protocol to prohibit redistribution of routes

Strona 206

Routing Commands284ProSafe M4100 and M7100 Managed Switches passive-interface (OSPF)Use this command to set the interface or tunnel as passive. It ove

Strona 207

Routing Commands285 ProSafe M4100 and M7100 Managed Switchestimers pacing lsa-groupTo adjust how OSPF groups LSAs for periodic refresh, use this comma

Strona 208

Routing Commands286ProSafe M4100 and M7100 Managed Switches trapflags (OSPF)Use this command to enable individual OSPF traps, enable a group of trap f

Strona 209

Routing Commands287 ProSafe M4100 and M7100 Managed Switchesno trapflags Use this command to revert to the default reference bandwidth. • To disab

Strona 210

Routing Commands288ProSafe M4100 and M7100 Managed Switches show ip ospfThis command displays information relevant to the OSPF router. Format show ip

Strona 211

Routing Commands289 ProSafe M4100 and M7100 Managed SwitchesASBR StatusReflects whether the ASBR mode is enabled or disabled. Enable implies that the

Strona 212

Switching Commands29 ProSafe M4100 and M7100 Managed SwitchesIPv6 Prefix isThe IPv6 address of the interface.MTU sizeThe maximum transmission size for

Strona 213 - • MVR Commands

Routing Commands290ProSafe M4100 and M7100 Managed Switches The following shows example CLI display output for the command.(Switch) #show ip ospfRoute

Strona 214 - MVR Commands

Routing Commands291 ProSafe M4100 and M7100 Managed SwitchesNumber of Active Areas... 3 (3 normal, 0 stub, 0 nssa) ABR Status...

Strona 215

AreaIDExternal RoutingSpf RunsArea Border Router CountArea LSA CountArea LSA ChecksumImport Summary LSAsOSPF Stub Metric ValueRouting Commands292ProSa

Strona 216

Routing Commands293 ProSafe M4100 and M7100 Managed Switchesshow ip ospf asbr This command displays the internal OSPF routing table entries to Autonom

Strona 217

Routing Commands294ProSafe M4100 and M7100 Managed Switches The information below is only displayed if OSPF is enabled.Format show ip ospf [<areaid

Strona 218

Routing Commands295 ProSafe M4100 and M7100 Managed Switchesshow ip ospf interface This command displays the information for the IFO object or virtual

Strona 219 - Example:

Routing Commands296ProSafe M4100 and M7100 Managed Switches The information below will only be displayed if OSPF is enabled.OSPF Interface TypeStateDe

Strona 220

Routing Commands297 ProSafe M4100 and M7100 Managed Switchesshow ip ospf interface stats This command displays the statistics for a specific interface

Strona 221 - Routing Commands

Routing Commands298ProSafe M4100 and M7100 Managed Switches The command lists the number of OSPF packets of each type sent and received on the interfa

Strona 222

Routing Commands299 ProSafe M4100 and M7100 Managed Switchesshow ip ospf neighbor This command displays information about OSPF neighbors. If you do no

Strona 223

3ContentsChapter 1 Using the Command-Line InterfaceLicensing and Command Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Com

Strona 224

Switching Commands30ProSafe M4100 and M7100 Managed Switches Spanning Tree Protocol (STP) CommandsThis section describes the commands you use to confi

Strona 225

Routing Commands300ProSafe M4100 and M7100 Managed Switches If you specify an IP address for the neighbor router, the following fields display:Interfa

Strona 226

Routing Commands301 ProSafe M4100 and M7100 Managed Switchesshow ip ospf rangeThis command displays information about the area ranges for the specifie

Strona 227 - IP Routing Commands

Routing Commands302ProSafe M4100 and M7100 Managed Switches show ip ospf stub tableThis command displays the OSPF stub table. The information below wi

Strona 228

Routing Commands303 ProSafe M4100 and M7100 Managed SwitchesThe following shows example CLI display output for the command. (netgear switch) #show ip

Strona 229

Routing Commands304ProSafe M4100 and M7100 Managed Switches show ip ospf virtual-link briefThis command displays the OSPF Virtual Interface informatio

Strona 230

Routing Commands305 ProSafe M4100 and M7100 Managed Switchesavoiding announcement of a topology change and the potential for flooding of LSAs and shor

Strona 231

Routing Commands306ProSafe M4100 and M7100 Managed Switches set long enough to allow the restarting router to reestablish all of its adjacencies and c

Strona 232

Routing Commands307 ProSafe M4100 and M7100 Managed Switchesnsf helper disableUse this command to disable helpful neighbor functionality for OSPF.Note

Strona 233

Routing Commands308ProSafe M4100 and M7100 Managed Switches max-metric router-lsaTo configure OSPF to enter stub router mode, use this command in Rout

Strona 234

Routing Commands309 ProSafe M4100 and M7100 Managed Switchesthe command no max-metric router-lsa on-startup. The command no max-metric router-lsa summ

Strona 235

Switching Commands31 ProSafe M4100 and M7100 Managed Switchesno spanning-tree bpdufilterUse this command to disable BPDU Filter on the interface or ra

Strona 236

Routing Commands310ProSafe M4100 and M7100 Managed Switches show dampening interfaceThis command summarizes the number of interfaces configured with d

Strona 237

Routing Commands311 ProSafe M4100 and M7100 Managed Switches Any change in the dampening configuration resets the current penalty, reuse time, and sup

Strona 238

Routing Commands312ProSafe M4100 and M7100 Managed Switches ip ripThis command enables RIP on a router interface.DefaultFormat ip ripModeno ip ripThis

Strona 239

Routing Commands313 ProSafe M4100 and M7100 Managed Switchesdefault-metric (RIP)This command is used to set a default for the metric of distributed ro

Strona 240

Routing Commands314ProSafe M4100 and M7100 Managed Switches no distribute-list outThis command is used to specify the access list to filter routes rec

Strona 241

Routing Commands315 ProSafe M4100 and M7100 Managed Switchesno ip rip receive version This command configures the interface to allow RIP control packe

Strona 242

Routing Commands316ProSafe M4100 and M7100 Managed Switches split-horizonThis command sets the RIP split horizon mode. Split horizon is a technique fo

Strona 243

Routing Commands317 ProSafe M4100 and M7100 Managed Switchesshow ip rip This command displays information relevant to the RIP router.Format show ip r

Strona 244

Routing Commands318ProSafe M4100 and M7100 Managed Switches show ip rip interface This command displays information related to a particular RIP interf

Strona 245

Routing Commands319 ProSafe M4100 and M7100 Managed Switchesip unreachablesUse this command to enable the generation of ICMP Destination Unreachable m

Strona 246

Switching Commands32ProSafe M4100 and M7100 Managed Switches spanning-tree bpduguardUse this command to enable BPDU Guard on the switch.DefaultFormat

Strona 247

Routing Commands320ProSafe M4100 and M7100 Managed Switches no ip icmp echo-replyUse this command to prevent the generation of ICMP Echo Reply message

Strona 248 - Virtual LAN Routing Commands

32155. IP Multicast CommandsThis chapter describes the IP Multicast commands available in the managed switch CLI. Note: Some commands described in

Strona 249

IP Multicast Commands322ProSafe M4100 and M7100 Managed Switches no ip mcast boundaryThis command deletes an administrative scope multicast boundary s

Strona 250

IP Multicast Commands323 ProSafe M4100 and M7100 Managed Switchesno ip multicast ttl-thresholdThis command applies the default <ttlthreshold> to

Strona 251

IP Multicast Commands324ProSafe M4100 and M7100 Managed Switches show ip mcast boundaryThis command displays all the configured administrative scoped

Strona 252

IP Multicast Commands325 ProSafe M4100 and M7100 Managed SwitchesIf you use the detail parameter, the command displays the following fields:Source IPG

Strona 253

IP Multicast Commands326ProSafe M4100 and M7100 Managed Switches show ip mcast mroute sourceThis command displays the multicast configuration settings

Strona 254

IP Multicast Commands327 ProSafe M4100 and M7100 Managed Switchesip dvmrp(Global Config)This command sets administrative mode of DVMRP in the router t

Strona 255

IP Multicast Commands328ProSafe M4100 and M7100 Managed Switches no ip dvmrp trapflagsThis command disables the DVMRP trap mode.Format no ip dvmrp tra

Strona 256

IP Multicast Commands329 ProSafe M4100 and M7100 Managed Switchesshow ip dvmrp interfaceThis command displays the interface information for DVMRP on t

Strona 257 - DHCP and BOOTP Relay Commands

Switching Commands33 ProSafe M4100 and M7100 Managed Switchesspanning-tree configuration revisionThis command sets the Configuration Identifier Revisi

Strona 258

IfIndexNbr IP AddrStateUp TimeExpiry TimeGeneration IDMajor VersionMinor VersionCapabilitiesReceived RoutesRcvd Bad PktsRcvd Bad RoutesIP Multicast Co

Strona 259 - IP Helper Commands

IP Multicast Commands331 ProSafe M4100 and M7100 Managed Switchesshow ip dvmrp pruneThis command displays the table listing the router’s upstream prun

Strona 260

IP Multicast Commands332ProSafe M4100 and M7100 Managed Switches routing across the Internet, independent of the mechanisms provided by any particular

Strona 261

IP Multicast Commands333 ProSafe M4100 and M7100 Managed Switchesno ip pim hello-intervalThis command resets the transmission frequency of hello messa

Strona 262

IP Multicast Commands334ProSafe M4100 and M7100 Managed Switches Join Prune Interval (secs) 60DR Priority NABSR Border DisabledNeighbor Count 1Designa

Strona 263

IP Multicast Commands335 ProSafe M4100 and M7100 Managed Switchesno ip pim sparse(Global Config)This command is used to administratively disable PIM-S

Strona 264 - 1583compatibility

IP Multicast Commands336ProSafe M4100 and M7100 Managed Switches no ip pim bsr-candidateThis command is used to disable the router to announce its can

Strona 265

IP Multicast Commands337 ProSafe M4100 and M7100 Managed Switches<groupaddress> is the group address supported by the RP. The parameter <grou

Strona 266

IP Multicast Commands338ProSafe M4100 and M7100 Managed Switches ip pim ssmUse this command to define the Source Specific Multicast (SSM) range of IP

Strona 267

PIM ModeInterfaceInterface-ModeOperational-StatusIP Multicast Commands339 ProSafe M4100 and M7100 Managed SwitchesExample 1:(Switch) #show ip pimPIM M

Strona 268

Switching Commands34ProSafe M4100 and M7100 Managed Switches • Use 802.1s to specify that the switch transmits MST BPDUs (IEEE 802.1s functionalit

Strona 269

IP Multicast Commands340ProSafe M4100 and M7100 Managed Switches show ip pim bsr-routerThis command displays the bootstrap router (BSR) information. T

Strona 270

IP Multicast Commands341 ProSafe M4100 and M7100 Managed Switchesshow ip pim rp mappingThis command displays the mappings for the PIM group to the act

Strona 271

IP Multicast Commands342ProSafe M4100 and M7100 Managed Switches Group Mask 255.255.0.0Origin StaticExpiry Time (hh:mm:ss) NAInternet Group Message Pr

Strona 272

IP Multicast Commands343 ProSafe M4100 and M7100 Managed Switchesip igmp last-member-query-countThis command sets the number of Group-Specific Queries

Strona 273

IP Multicast Commands344ProSafe M4100 and M7100 Managed Switches no ip igmp query-intervalThis command resets the query interval for the specified int

Strona 274

IP Multicast Commands345 ProSafe M4100 and M7100 Managed Switchesip igmp startup-query-countThis command sets the number of Queries sent out on startu

Strona 275

IGMP Admin ModeInterfaceInterface-ModeOperational-StatusIP Multicast Commands346ProSafe M4100 and M7100 Managed Switches show ip igmp groupsThis comma

Strona 276

IP Multicast Commands347 ProSafe M4100 and M7100 Managed Switchesshow ip igmp interfaceThis command displays the IGMP information for the interface. F

Strona 277

IP Multicast Commands348ProSafe M4100 and M7100 Managed Switches show ip igmp interface membershipThis command displays the list of interfaces that ha

Strona 278

Querier StatusQuerier IP AddressQuerier Up TimeQuerier Expiry TimeWrong Version QueriesNumber of JoinsNumber of GroupsIP Multicast Commands349 ProSafe

Strona 279

Switching Commands35 ProSafe M4100 and M7100 Managed Switchesspanning-tree tcnguardThis command enables the propagation of received topology change no

Strona 280

IP Multicast Commands350ProSafe M4100 and M7100 Managed Switches ip igmp-proxy unsolicit-rprt-intervalThis command sets the unsolicited report interva

Strona 281

IP Multicast Commands351 ProSafe M4100 and M7100 Managed SwitchesExample: The following example shows CLI display output for the command.(Switch) #sho

Strona 282

IP Multicast Commands352ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command.(Switch) #sho

Strona 283

IP Multicast Commands353 ProSafe M4100 and M7100 Managed SwitchesExample: The following shows example CLI display output for the command.(Switch) #sho

Strona 284

IP Multicast Commands354ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command.(Switch) #sho

Strona 285

35566. IPv6 CommandsThis chapter describes the IPv6 commands available in the managed switch CLI. Note: Some commands described in this chapter req

Strona 286 - Table 1. Trapflags Groups

IPv6 Commands356ProSafe M4100 and M7100 Managed Switches Tunnel Interface CommandsThe commands in this section describe how to create, delete, and man

Strona 287

IPv6 Commands357 ProSafe M4100 and M7100 Managed Switchestunnel mode ipv6ipThis command specifies the mode of the tunnel. With the optional 6to4 argum

Strona 288

IPv6 Commands358ProSafe M4100 and M7100 Managed Switches ipv6 hop-limitThis command defines the unicast hop count used in ipv6 packets originated by t

Strona 289

IPv6 Commands359 ProSafe M4100 and M7100 Managed Switchesno ipv6 enableUse this command to disable IPv6 routing on an interface.Format no ipv6 enableM

Strona 290

Switching Commands36ProSafe M4100 and M7100 Managed Switches no spanning-tree max-hopsThis command sets the Bridge Max Hops parameter for the Common a

Strona 291

IPv6 Commands360ProSafe M4100 and M7100 Managed Switches ipv6 address autoconfigThis command is used to enable stateless address autoconfiguration cap

Strona 292

IPv6 Commands361 ProSafe M4100 and M7100 Managed Switchesusing a link-local address as the next hop. A route with a preference of 255 cannot be used t

Strona 293

IPv6 Commands362ProSafe M4100 and M7100 Managed Switches ipv6 mtuThis command sets the maximum transmission unit (MTU) size, in bytes, of IPv6 packets

Strona 294

IPv6 Commands363 ProSafe M4100 and M7100 Managed Switchesipv6 nd managed-config-flagThis command sets the “managed address configuration” flag in rout

Strona 295

IPv6 Commands364ProSafe M4100 and M7100 Managed Switches no ipv6 nd other-config-flagThis command resets the “other stateful configuration” flag back

Strona 296

IPv6 Commands365 ProSafe M4100 and M7100 Managed Switchesipv6 nd reachable-timeThis command sets the router advertisement time to consider a neighbor

Strona 297

IPv6 Commands366ProSafe M4100 and M7100 Managed Switches ipv6 nd router-preferenceFormat no ipv6 router-preferenceModeThis command will set the router

Strona 298

IPv6 Commands367 ProSafe M4100 and M7100 Managed Switchesno ipv6 icmp error-intervalUse the no form of the command to return burst-interval and burst-

Strona 299

IPv6 Commands368ProSafe M4100 and M7100 Managed Switches show ipv6 interfaceUse this command to show the usability status of IPv6 interfaces and wheth

Strona 300

IPv6 Commands369 ProSafe M4100 and M7100 Managed SwitchesExample: The following shows example CLI display output for the command.(Switch) #show ipv6 i

Strona 301

Switching Commands37 ProSafe M4100 and M7100 Managed SwitchesIf you specify cost, this command sets the path cost for this port within a multiple span

Strona 302

IPv6 Commands370ProSafe M4100 and M7100 Managed Switches show ipv6 neighborUse this command to display information about the IPv6 neighbors.Format sho

Strona 303

IPv6 Commands371 ProSafe M4100 and M7100 Managed SwitchesNote: If you use the connected keyword for <protocol>, the all option is not available

Strona 304

IPv6 Commands372ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command.(Switch) #show ipv6 r

Strona 305

IPv6 Commands373 ProSafe M4100 and M7100 Managed Switchesshow ipv6 route preferencesUse this command to show the preference value associated with the

Strona 306

IPv6 Commands374ProSafe M4100 and M7100 Managed Switches The following example shows CLI display output for the command.(switch) #show ipv6 route summ

Strona 307

IPv6 Commands375 ProSafe M4100 and M7100 Managed SwitchesOSPF Routes... 13 Intra Area Routes...

Strona 308

IPv6 Commands376ProSafe M4100 and M7100 Managed Switches show ipv6 trafficUse this command to show traffic and statistics for IPv6 and ICMPv6. Specify

Strona 309 - Dampening

IPv6 Commands377 ProSafe M4100 and M7100 Managed SwitchesReceived Datagrams Discarded OtherNumber of input IPv6 datagrams for which no problems were e

Strona 310

IPv6 Commands378ProSafe M4100 and M7100 Managed Switches ICMPv6 Messages with errorsNumber of ICMP messages which the interface received but determine

Strona 311

IPv6 Commands379 ProSafe M4100 and M7100 Managed Switchesclear ipv6 route countersThis command resets to zero the IPv6 routing table counters reported

Strona 312

Switching Commands38ProSafe M4100 and M7100 Managed Switches are masked according to the 802.1s specification. This causes the priority to be rounded

Strona 313

IPv6 Commands380ProSafe M4100 and M7100 Managed Switches clear ipv6 statisticsUse this command to clear IPv6 statistics for all interfaces or for a sp

Strona 314

IPv6 Commands381 ProSafe M4100 and M7100 Managed Switchesipv6 ospf cost This command configures the cost on an OSPF interface. The <cost> parame

Strona 315

IPv6 Commands382ProSafe M4100 and M7100 Managed Switches no ipv6 ospf hello-interval This command sets the default OSPF hello interval for the specifi

Strona 316

IPv6 Commands383 ProSafe M4100 and M7100 Managed Switchesno ipv6 ospf networkThis command sets the interface type to the default value.Format no ipv6

Strona 317

IPv6 Commands384ProSafe M4100 and M7100 Managed Switches ipv6 ospf transmit-delay This command sets the OSPF Transit Delay for the specified interface

Strona 318 - ICMP Throttling Commands

IPv6 Commands385 ProSafe M4100 and M7100 Managed Switchesno area nssa(OSPFv3) This command disables nssa from the specified area id.Format no area <

Strona 319

IPv6 Commands386ProSafe M4100 and M7100 Managed Switches area nssa no-summary (OSPFv3)This command configures the NSSA so that summary LSAs are not ad

Strona 320

IPv6 Commands387 ProSafe M4100 and M7100 Managed Switchesno area nssa translator-stab-intv (OSPFv3)This command disables the nssa translator’s <sta

Strona 321 - IP Multicast Commands

IPv6 Commands388ProSafe M4100 and M7100 Managed Switches area stub no-summary (OSPFv3)This command disables the import of Summary LSAs for the stub ar

Strona 322 - IP Multicast Commands

IPv6 Commands389 ProSafe M4100 and M7100 Managed Switchesno area virtual-link dead-interval(OSPFv3)This command configures the default dead interval f

Strona 323

Switching Commands39 ProSafe M4100 and M7100 Managed Switchesspanning-tree port modeThis command sets the Administrative Switch Port State for this po

Strona 324

IPv6 Commands390ProSafe M4100 and M7100 Managed Switches no area virtual-link retransmit-interval(OSPFv3)This command configures the default retransmi

Strona 325

IPv6 Commands391 ProSafe M4100 and M7100 Managed Switchesno auto-cost reference-bandwidth (OSPFv3)Use this command to set the reference bandwidth to t

Strona 326 - DVMRP Commands

IPv6 Commands392ProSafe M4100 and M7100 Managed Switches clear ipv6 ospf neighbor interface To drop adjacency with all neighbors on a specific interfa

Strona 327

IPv6 Commands393 ProSafe M4100 and M7100 Managed Switchesno default-metric (OSPFv3)This command is used to set a default for the metric of distributed

Strona 328

IPv6 Commands394ProSafe M4100 and M7100 Managed Switches exit-overflow-interval (OSPFv3)This command configures the exit overflow interval for OSPF. I

Strona 329

IPv6 Commands395 ProSafe M4100 and M7100 Managed Switchesmaximum-paths (OSPFv3)This command sets the number of paths that OSPF can report for a given

Strona 330

IPv6 Commands396ProSafe M4100 and M7100 Managed Switches no passive-interface(OSPFv3)Use this command to set the interface or tunnel as non-passive. I

Strona 331 - PIM Commands

IPv6 Commands397 ProSafe M4100 and M7100 Managed Switchestrapflags (OSPFv3)Use this command to enable individual OSPF traps, enable a group of trap fl

Strona 332

IPv6 Commands398ProSafe M4100 and M7100 Managed Switches • To enable all the flags, give the command as trapflags all.DefaultFormat trapflags { al

Strona 333

IPv6 Commands399 ProSafe M4100 and M7100 Managed SwitchesNote: Some of the information below displays only if you enable OSPF and configure certain f

Strona 334

4ProSafe M4100 and M7100 Managed SwitchesIGMP Snooping Configuration Commands . . . . . . . . . . . . . . . . . . . . . . .148IGMP Snooping Querier C

Strona 335

Switching Commands40ProSafe M4100 and M7100 Managed Switches spanning-tree bpduforwardingNormally a switch will not forward Spanning Tree Protocol (ST

Strona 336

IPv6 Commands400ProSafe M4100 and M7100 Managed Switches Maximum Number of Retransmit EntriesThe maximum number of LSAs that can be waiting for acknow

Strona 337

IPv6 Commands401 ProSafe M4100 and M7100 Managed Switchesshow ipv6 ospf abrThis command displays the internal OSPFv3 routes to reach Area Border Route

Strona 338

IPv6 Commands402ProSafe M4100 and M7100 Managed Switches The following OSPF NSSA-specific information displays only if the area is configured as an NS

Strona 339 - Example 2:

IPv6 Commands403 ProSafe M4100 and M7100 Managed Switchesshow ipv6 ospf database This command displays information about the link state database when

Strona 340 - Privileged EXEC

IPv6 Commands404ProSafe M4100 and M7100 Managed Switches show ipv6 ospf database database-summaryUse this command to display the number of each type o

Strona 341 - Example 4:

IPv6 Commands405 ProSafe M4100 and M7100 Managed SwitchesThe following information only displays if OSPF is initialized on the interface:OSPF Interfac

Strona 342

IPv6 Commands406ProSafe M4100 and M7100 Managed Switches show ipv6 ospf interface statsThis command displays the statistics for a specific interface.

Strona 343

IPv6 Commands407 ProSafe M4100 and M7100 Managed SwitchesSee show ip ospf interface stats on page 297 for a sample output of the number of OSPF packe

Strona 344

IPv6 Commands408ProSafe M4100 and M7100 Managed Switches If you do not specify an IP address, a table with the following columns displays for all neig

Strona 345

IPv6 Commands409 ProSafe M4100 and M7100 Managed Switchesshow ipv6 ospf rangeThis command displays information about the area ranges for the specified

Strona 346

Switching Commands41 ProSafe M4100 and M7100 Managed Switchesshow spanning-tree briefThis command displays spanning tree settings for the bridge. The

Strona 347

IPv6 Commands410ProSafe M4100 and M7100 Managed Switches show ipv6 ospf virtual-link This command displays the OSPF Virtual Interface information for

Strona 348

IPv6 Commands411 ProSafe M4100 and M7100 Managed SwitchesOSPFv3 Graceful Restart CommandsThe managed switch implementation of OSPFv3 supports graceful

Strona 349 - IGMP Proxy Commands

IPv6 Commands412ProSafe M4100 and M7100 Managed Switches The grace LSA announcing the graceful restart includes the reason for the restart. Reasons 1

Strona 350

IPv6 Commands413 ProSafe M4100 and M7100 Managed Switchesno nsf [ietf] helper strict-lsa-checking (OSPFv3)This command allows OSPF to continue as a he

Strona 351

IPv6 Commands414ProSafe M4100 and M7100 Managed Switches ipv6 dhcp server Use this command to configure DHCPv6 server functionality on an interface. T

Strona 352

IPv6 Commands415 ProSafe M4100 and M7100 Managed SwitchesThese pools are shared between multiple interfaces over which DHCPv6 server capabilities are

Strona 353

IPv6 Commands416ProSafe M4100 and M7100 Managed Switches prefix-delegation (IPv6)Multiple IPv6 prefixes can be defined within a pool for distributing

Strona 354

IPv6 Commands417 ProSafe M4100 and M7100 Managed SwitchesTerm DefinitionDHCPv6 Solicit Packets ReceivedNumber of solicit received statistics.DHCPv6 Re

Strona 355 - IPv6 Commands

IPv6 Commands418ProSafe M4100 and M7100 Managed Switches show ipv6 dhcp interfaceThis command displays DHCPv6 information for all relevant interfaces

Strona 356 - Tunnel Interface Commands

IPv6 Commands419 ProSafe M4100 and M7100 Managed Switchesshow ipv6 dhcp poolThis command displays configured DHCP pool.Format show ipv6 dhcp pool <

Strona 357 - IPv6 Routing Commands

Switching Commands42ProSafe M4100 and M7100 Managed Switches show spanning-tree interfaceThis command displays the settings and parameters for a speci

Strona 358

IPv6 Commands420ProSafe M4100 and M7100 Managed Switches Valid LifetimeValid lifetime in seconds for delegated prefix.Preferred LifetimePreferred life

Strona 359 - 3ffe:1::1234/64

42177. IPv6 Multicast CommandsThis chapter describes the IPv6 multicast commands available in the managed switch CLI.Note: Some commands described

Strona 360

IPv6 Multicast Commands422ProSafe M4100 and M7100 Managed Switches IPv6 Multicast Forwarder CommandsNote: There is no specific IP multicast enable fo

Strona 361

IPv6 Multicast Commands423 ProSafe M4100 and M7100 Managed Switchesshow ipv6 mroute groupThis command displays the multicast configuration settings sp

Strona 362

IPv6 Multicast Commands424ProSafe M4100 and M7100 Managed Switches If you use the summary parameter, the command displays the following column heading

Strona 363

IPv6 Multicast Commands425 ProSafe M4100 and M7100 Managed Switchesno ipv6 pim (Interface Config)Use this command to set the administrative mode of P

Strona 364

IPv6 Multicast Commands426ProSafe M4100 and M7100 Managed Switches PIM Mode... DenseData Threshold Rate (Kbps)...

Strona 365

IPv6 Multicast Commands427 ProSafe M4100 and M7100 Managed Switches(Switch) #show ipv6 pim interface 0/1Interface...

Strona 366

IPv6 Multicast Commands428ProSafe M4100 and M7100 Managed Switches no ipv6 pim bsr-candidateUse this command to disable the router to announce its can

Strona 367

IPv6 Multicast Commands429 ProSafe M4100 and M7100 Managed Switchesipv6 pim join-prune-intervalUse this command to configure the interface join/prune

Strona 368

Switching Commands43 ProSafe M4100 and M7100 Managed Switchescorresponds to the desired existing multiple spanning tree instance. The <slot/port>

Strona 369

IPv6 Multicast Commands430ProSafe M4100 and M7100 Managed Switches no ipv6 pim rp-candidateUse this command to disable the router to advertise itself

Strona 370

BSR AddressUptimeBSR PriorityHash Mask LengthNext Bootstrap Message InNext Candidate RP advertisement inIPv6 Multicast Commands431 ProSafe M4100 and M

Strona 371 - C - connected, S - static

IPv6 Multicast Commands432ProSafe M4100 and M7100 Managed Switches network. In this situation, the 7000 series has an IGMP/MLD Snooping Querier runnin

Strona 372

IPv6 Multicast Commands433 ProSafe M4100 and M7100 Managed Switchessent on that interface. The range for <query-max-response-time> is 0–65,535 m

Strona 373

IPv6 Multicast Commands434ProSafe M4100 and M7100 Managed Switches no ipv6 mld last-member-query-countUse this command to reset the <last-member-qu

Strona 374

IPv6 Multicast Commands435 ProSafe M4100 and M7100 Managed SwitchesThe following table is displayed to indicate all the sources associated with this g

Strona 375

IPv6 Multicast Commands436ProSafe M4100 and M7100 Managed Switches The following information is displayed for each of the interfaces or for only the s

Strona 376 - ::0) and unsupported

IPv6 Multicast Commands437 ProSafe M4100 and M7100 Managed Switchesshow ipv6 mld trafficUse this command to display MLD statistical information for th

Strona 377

IPv6 Multicast Commands438ProSafe M4100 and M7100 Managed Switches ipv6 mld-proxyUse this command to enable MLD-Proxy on the router. To enable MLD-Pro

Strona 378

IPv6 Multicast Commands439 ProSafe M4100 and M7100 Managed Switchesshow ipv6 mld-proxyUse this command to display a summary of the host interface stat

Strona 379

Switching Commands44ProSafe M4100 and M7100 Managed Switches If you specify 0 (defined as the default CIST ID) as the <mstid>, this command disp

Strona 380 - OSPFv3 Commands

IPv6 Multicast Commands440ProSafe M4100 and M7100 Managed Switches show ipv6 mld-proxy interfaceThis command displays a detailed list of the host inte

Strona 381

IPv6 Multicast Commands441 ProSafe M4100 and M7100 Managed SwitchesExample: The following shows example CLI display output for the command.(Switch) #s

Strona 382

IPv6 Multicast Commands442ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command.(Switch) #s

Strona 383

44388. Quality of Service (QoS) CommandsThis chapter describes the Quality of Service (QoS) commands available in the managed switch CLI. This chapt

Strona 384

Quality of Service (QoS) Commands444ProSafe M4100 and M7100 Managed Switches Class of Service (CoS) CommandsThis section describes the commands you us

Strona 385

Quality of Service (QoS) Commands445 ProSafe M4100 and M7100 Managed Switchesno classofservice ip-dscp-mapping This command maps each IP DSCP value to

Strona 386

Quality of Service (QoS) Commands446ProSafe M4100 and M7100 Managed Switches cos-queue strictThis command activates the strict priority scheduler mode

Strona 387

Quality of Service (QoS) Commands447 ProSafe M4100 and M7100 Managed Switchesrandom-detect exponential weighting-constantUse this command to configure

Strona 388

Quality of Service (QoS) Commands448ProSafe M4100 and M7100 Managed Switches no random-detect queue-parmsUse this command to set the WRED configuratio

Strona 389

Quality of Service (QoS) Commands449 ProSafe M4100 and M7100 Managed Switchesshow classofservice ip-precedence-mappingThis command displays the curren

Strona 390

Switching Commands45 ProSafe M4100 and M7100 Managed Switchesshow spanning-tree mst port summaryThis command displays the settings of one or all ports

Strona 391

Non-IP Traffic ClassUntrusted Traffic ClassQuality of Service (QoS) Commands450ProSafe M4100 and M7100 Managed Switches show interfaces cos-queueThis

Strona 392

Quality of Service (QoS) Commands451 ProSafe M4100 and M7100 Managed Switchesshow interfaces random-detectThis command displays the global WRED settin

Strona 393

Quality of Service (QoS) Commands452ProSafe M4100 and M7100 Managed Switches The following rules apply when you create a DiffServ class:• Each cla

Strona 394

Quality of Service (QoS) Commands453 ProSafe M4100 and M7100 Managed SwitchesThis set of commands consists of class creation/deletion and matching, wi

Strona 395

Quality of Service (QoS) Commands454ProSafe M4100 and M7100 Managed Switches no class-mapThis command eliminates an existing DiffServ class. The <c

Strona 396

Quality of Service (QoS) Commands455 ProSafe M4100 and M7100 Managed Switchesmatch class-mapThis command adds to the specified class definition the se

Strona 397

Quality of Service (QoS) Commands456ProSafe M4100 and M7100 Managed Switches match secondary cosThis command adds to the specified class definition a

Strona 398

Quality of Service (QoS) Commands457 ProSafe M4100 and M7100 Managed Switchesmatch dstip6This command adds to the specified class definition a match c

Strona 399

Quality of Service (QoS) Commands458ProSafe M4100 and M7100 Managed Switches match ip precedenceThis command adds to the specified class definition a

Strona 400

Quality of Service (QoS) Commands459 ProSafe M4100 and M7100 Managed Switchesmatch protocol This command adds to the specified class definition a matc

Strona 401

Switching Commands46ProSafe M4100 and M7100 Managed Switches show spanning-tree mst summaryThis command displays summary information about all multipl

Strona 402

Quality of Service (QoS) Commands460ProSafe M4100 and M7100 Managed Switches parameter specifies an IP address bit mask and must consist of a contiguo

Strona 403

Quality of Service (QoS) Commands461 ProSafe M4100 and M7100 Managed Switchesmatch secondary-vlanThis command adds to the specified class definition a

Strona 404

Quality of Service (QoS) Commands462ProSafe M4100 and M7100 Managed Switches dropThis command specifies that all packets for the associated traffic st

Strona 405

Quality of Service (QoS) Commands463 ProSafe M4100 and M7100 Managed Switchesclass This command creates an instance of a class definition within the s

Strona 406

Quality of Service (QoS) Commands464ProSafe M4100 and M7100 Managed Switches mark cos-as-sec-cosThis command marks outer VLAN tag priority bits of all

Strona 407

Quality of Service (QoS) Commands465 ProSafe M4100 and M7100 Managed Switchespolice-simpleThis command is used to establish the traffic policing style

Strona 408

Quality of Service (QoS) Commands466ProSafe M4100 and M7100 Managed Switches policy-mapThis command establishes a new DiffServ policy. The <policyn

Strona 409

Quality of Service (QoS) Commands467 ProSafe M4100 and M7100 Managed Switchesservice-policyThis command attaches a policy to an interface in the inbou

Strona 410

Quality of Service (QoS) Commands468ProSafe M4100 and M7100 Managed Switches DiffServ Show CommandsUse the DiffServ show commands to display configura

Strona 411

Quality of Service (QoS) Commands469 ProSafe M4100 and M7100 Managed Switchesshow diffservThis command displays the DiffServ General Status Group info

Strona 412

Spanning Tree AdminmodeSpanning Tree VersionBPDU Guard ModeBPDU Filter ModeConfiguration NameConfiguration Revision LevelConfiguration Digest KeyConfi

Strona 413 - DHCPv6 Commands

Quality of Service (QoS) Commands470ProSafe M4100 and M7100 Managed Switches The following information is repeated for each class associated with this

Strona 414 - FF02::1:2)

Quality of Service (QoS) Commands471 ProSafe M4100 and M7100 Managed SwitchesIf the Policy Name is not specified this command displays a list of all d

Strona 415

DiffServ Admin ModeQuality of Service (QoS) Commands472ProSafe M4100 and M7100 Managed Switches The following information is repeated for interface an

Strona 416

Quality of Service (QoS) Commands473 ProSafe M4100 and M7100 Managed Switchesshow service-policyThis command displays a summary of policy-oriented sta

Strona 417

Quality of Service (QoS) Commands474ProSafe M4100 and M7100 Managed Switches no mac access-list extended This command deletes a MAC ACL identified by

Strona 418

Quality of Service (QoS) Commands475 ProSafe M4100 and M7100 Managed Switchesibmsna, ipv4, ipv6, ipx, mplsmcast, mplsucast, netbios, novell, pppoe, ra

Strona 419 - [<ipv6-address>]

Quality of Service (QoS) Commands476ProSafe M4100 and M7100 Managed Switches mac access-group This command either attaches a specific MAC access contr

Strona 420

Quality of Service (QoS) Commands477 ProSafe M4100 and M7100 Managed Switchesno mac access-group This command removes a MAC ACL identified by <name

Strona 421 - IPv6 Multicast Commands

Quality of Service (QoS) Commands478ProSafe M4100 and M7100 Managed Switches IP Access Control List (ACL) CommandsThis section describes the commands

Strona 422

Quality of Service (QoS) Commands479 ProSafe M4100 and M7100 Managed Switchesno access-listThis command deletes an IP ACL that is identified by the pa

Strona 423

Switching Commands48ProSafe M4100 and M7100 Managed Switches vlan databaseThis command gives you access to the VLAN Config mode, which allows you to c

Strona 424 - IPv6 PIM Commands

Quality of Service (QoS) Commands480ProSafe M4100 and M7100 Managed Switches If an IP ACL by this name exists, this command enters IPv4-Access_List co

Strona 425

Quality of Service (QoS) Commands481 ProSafe M4100 and M7100 Managed SwitchesNote: The mirror parameter allows traffic matching this rule to be copie

Strona 426

Quality of Service (QoS) Commands482ProSafe M4100 and M7100 Managed Switches number indicates higher precedence order. If a sequence number is already

Strona 427

Quality of Service (QoS) Commands483 ProSafe M4100 and M7100 Managed Switchesshow ip access-listsThis command displays an IP ACL <accesslistnumber&

Strona 428

Quality of Service (QoS) Commands484ProSafe M4100 and M7100 Managed Switches show access-listsThis command displays IP ACLs, IPv6 ACLs, and MAC access

Strona 429

Quality of Service (QoS) Commands485 ProSafe M4100 and M7100 Managed Switchesno ipv6 access-listThis command deletes the IPv6 ACL identified by <na

Strona 430

Quality of Service (QoS) Commands486ProSafe M4100 and M7100 Managed Switches number of user configurable queues available for the hardware platform. T

Strona 431 - IPv6 MLD Commands

Quality of Service (QoS) Commands487 ProSafe M4100 and M7100 Managed Switchesno ipv6 traffic-filterThis command removes an IPv6 ACL identified by <

Strona 432

Quality of Service (QoS) Commands488ProSafe M4100 and M7100 Managed Switches Time Range Commands for Time-Based ACLsTime-based ACLs allow one or more

Strona 433

Quality of Service (QoS) Commands489 ProSafe M4100 and M7100 Managed Switchestime zone. The [start time date] parameters indicate the time and date at

Strona 434

Switching Commands49 ProSafe M4100 and M7100 Managed Switchesvlan acceptframeThis command sets the frame acceptance mode per interface. For VLAN Only

Strona 435

Quality of Service (QoS) Commands490ProSafe M4100 and M7100 Managed Switches no periodicUse this command to delete a periodic time entry from a time r

Strona 436

Quality of Service (QoS) Commands491 ProSafe M4100 and M7100 Managed SwitchesIn a VoIP system, various signaling protocols are used to establish the c

Strona 437 - IPv6 MLD-Proxy Commands

Quality of Service (QoS) Commands492ProSafe M4100 and M7100 Managed Switches no auto-voip oui This command is to delete already configured OUI.Format

Strona 438

Quality of Service (QoS) Commands493 ProSafe M4100 and M7100 Managed SwitchesNote: The administrator has to enable tagging on auto-VoIP-enabled ports

Strona 439

Quality of Service (QoS) Commands494ProSafe M4100 and M7100 Managed Switches Interface Auto VoIP Operational StatusMode--------- --------------

Strona 440

Quality of Service (QoS) Commands495 ProSafe M4100 and M7100 Managed Switches• Detecting the establishment and termination of iSCSI sessions and conne

Strona 441

Quality of Service (QoS) Commands496ProSafe M4100 and M7100 Managed Switches also choose to use these {unreserved} ports). When a port is already def

Strona 442

Quality of Service (QoS) Commands497 ProSafe M4100 and M7100 Managed SwitchesNote: SCSI flows are assigned by default to the highest VPT/DSCP mapped

Strona 443

Quality of Service (QoS) Commands498ProSafe M4100 and M7100 Managed Switches • When aging time is increased - Current sessions will be timed out accor

Strona 444

Quality of Service (QoS) Commands499 ProSafe M4100 and M7100 Managed Switchesshow iscsi sessionsThe show iscsi sessions Privileged EXEC mode command d

Strona 445

5ProSafe M4100 and M7100 Managed SwitchesChapter 6 IPv6 CommandsTunnel Interface Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 446

Switching Commands50ProSafe M4100 and M7100 Managed Switches vlan makestaticThis command changes a dynamically created VLAN (one that is created by GV

Strona 447

Quality of Service (QoS) Commands500ProSafe M4100 and M7100 Managed Switches Time for aging out: 2 minISID: 22Initiator Initiator Target Target IP add

Strona 448 - [<slot/port>]

50199. Power over Ethernet (PoE) CommandsThis chapter contains the following sections:• About PoE • PoE Commands About PoEPower over Etherne

Strona 449

Power over Ethernet (PoE) Commands502ProSafe M4100 and M7100 Managed Switches PoE CommandspoeUse this command to enable the Power over Ethernet (PoE)

Strona 450

Power over Ethernet (PoE) Commands503 ProSafe M4100 and M7100 Managed Switchesno poe detectionUse this command to set the detection mode to the defaul

Strona 451

Power over Ethernet (PoE) Commands504ProSafe M4100 and M7100 Managed Switches • user-defined—Allows you to define the maximum power to the port. T

Strona 452 - DiffServ Class Commands

Power over Ethernet (PoE) Commands505 ProSafe M4100 and M7100 Managed SwitchesDynamic Power ManagementAvailable power = 300 watts - 3 watts = 297 watt

Strona 453 - Global Config

Power over Ethernet (PoE) Commands506ProSafe M4100 and M7100 Managed Switches this command takes effect only once after it is executed and cannot be s

Strona 454

Power over Ethernet (PoE) Commands507 ProSafe M4100 and M7100 Managed Switchesno poe timer schedule nameUse this command to detach the schedule from t

Strona 455

Power over Ethernet (PoE) Commands508ProSafe M4100 and M7100 Managed Switches no poe trapsUse this command to disable logging the PoE traps.show poeUs

Strona 456

Power over Ethernet (PoE) Commands509 ProSafe M4100 and M7100 Managed SwitchesExample:(switch) #show poeFirmware Version...

Strona 457

Switching Commands51 ProSafe M4100 and M7100 Managed Switchesvlan participation allThis command configures the degree of participation for all interfa

Strona 458

Power over Ethernet (PoE) Commands510ProSafe M4100 and M7100 Managed Switches show poe port infoUse this command to get information about the status o

Strona 459

Power over Ethernet (PoE) Commands511 ProSafe M4100 and M7100 Managed Switches High Max Output OutputIntf Power

Strona 460

5121010. Utility CommandsThis chapter describes the utility commands available in the CLI. This chapter contains the following sections:• Auto I

Strona 461 - DiffServ Policy Commands

Utility Commands513 ProSafe M4100 and M7100 Managed SwitchesAuto Install CommandsThis section describes the Auto Install Commands. Auto Install is a s

Strona 462

Utility Commands514ProSafe M4100 and M7100 Managed Switches boot host auto-saveThis command is used to enable automatically saving the downloaded conf

Strona 463

Utility Commands515 ProSafe M4100 and M7100 Managed Switchesno boot host retry-countThis command is used to reset the number to the default. The defau

Strona 464

Utility Commands516ProSafe M4100 and M7100 Managed Switches deleteThis command deletes the supplied image file from the permanent storage. The image t

Strona 465

Utility Commands517 ProSafe M4100 and M7100 Managed Switchesupdate bootcodeThis command updates the bootcode (boot loader) on the switch. The bootcode

Strona 466 - DiffServ Service Commands

Utility Commands518ProSafe M4100 and M7100 Managed Switches Note: Event log information is retained across a switch reset.show hardwareThis command d

Strona 467

Utility Commands519 ProSafe M4100 and M7100 Managed Switchesshow interface This command displays a summary of statistics for a specific interface or a

Strona 468 - DiffServ Show Commands

Switching Commands52ProSafe M4100 and M7100 Managed Switches assigned the value of the interface VLAN ID for this port. With either option, VLAN tagge

Strona 469

Utility Commands520ProSafe M4100 and M7100 Managed Switches The display parameters, when the argument is “switchport” are as follows:Packets Received

Strona 470

Utility Commands521 ProSafe M4100 and M7100 Managed Switchesshow interface ethernetThis command displays detailed statistics for a specific interface

Strona 471 - [in

Utility Commands522ProSafe M4100 and M7100 Managed Switches (cont) • Packets RX and TX 65–127 Octets - The total number of packets (including bad pack

Strona 472

Utility Commands523 ProSafe M4100 and M7100 Managed SwitchesPackets Received with MAC Errors• Total Packets Received with MAC Errors - The total numbe

Strona 473

Utility Commands524ProSafe M4100 and M7100 Managed Switches Packets Transmitted Octets• Total Packets Transmitted (Octets) - The total number of octet

Strona 474 - {deny

Utility Commands525 ProSafe M4100 and M7100 Managed SwitchesTransmit Discards • Total Transmit Packets Discards - The sum of single collision frames d

Strona 475

Utility Commands526ProSafe M4100 and M7100 Managed Switches If you use the switchport keyword, the following information appears.Term DefinitionOctets

Strona 476

Utility Commands527 ProSafe M4100 and M7100 Managed Switchesshow mac-addr-tableThis command displays the forwarding database entries. These entries ar

Strona 477

Utility Commands528ProSafe M4100 and M7100 Managed Switches If you enter the interface <slot/port> parameter, in addition to the MAC Address and

Strona 478

Utility Commands529 ProSafe M4100 and M7100 Managed Switchesfalling utilization threshold is optional. If the falling CPU utilization parameters are n

Strona 479

Switching Commands53 ProSafe M4100 and M7100 Managed Switchesvlan port tagging allThis command configures the tagging behavior for all interfaces in a

Strona 480 - {deny

Utility Commands530ProSafe M4100 and M7100 Managed Switches bcmCNTR.0 0.20% bcmLINK.0

Strona 481

Utility Commands531 ProSafe M4100 and M7100 Managed SwitchesNote: If you issue the show running-config command from a serial connection, access to th

Strona 482

Switch DescriptionSystem NameSystem LocationSystem ContactSystem Object IDSystem Up TimeMIBs SupportedUtility Commands532ProSafe M4100 and M7100 Manag

Strona 483

Utility Commands533 ProSafe M4100 and M7100 Managed Switcheslength Use this command to set the pagination length to value number of lines for the sess

Strona 484

Utility Commands534ProSafe M4100 and M7100 Managed Switches memory free low-watermark processorUse this command to get notifications when the CPU free

Strona 485 - {deny

Utility Commands535 ProSafe M4100 and M7100 Managed Switcheslogging buffered wrapThis command enables wrapping of in-memory logging when the log file

Strona 486

Utility Commands536ProSafe M4100 and M7100 Managed Switches no logging consoleThis command disables logging to the console.Format no logging consoleMo

Strona 487

Utility Commands537 ProSafe M4100 and M7100 Managed Switchesno logging syslogThis command disables syslog logging.Format no logging syslogModelogging

Strona 488

Utility Commands538ProSafe M4100 and M7100 Managed Switches show logging bufferedThis command displays buffered logging (system startup and system ope

Strona 489 - [end time date]

Number of Traps Since Last ResetTrap Log CapacityNumber of Traps Since Log Last ViewedLogSystem Time UpTrapUtility Commands539 ProSafe M4100 and M7100

Strona 490 - AutoVOIP

Switching Commands54ProSafe M4100 and M7100 Managed Switches no vlan protocol group nameThis command removes the name from a protocol-based VLAN group

Strona 491

Utility Commands540ProSafe M4100 and M7100 Managed Switches no logging emailThis command disables email alerting.Format no logging emailModelogging em

Strona 492

Utility Commands541 ProSafe M4100 and M7100 Managed Switchesno logging email message-type to-addrThis command removes the configured to-addr field of

Strona 493

Utility Commands542ProSafe M4100 and M7100 Managed Switches logging email logtimeThis command configures how frequently non-urgent email messages are

Strona 494

Utility Commands543 ProSafe M4100 and M7100 Managed Switchesshow logging email config This command displays information about the email alert configur

Strona 495

Utility Commands544ProSafe M4100 and M7100 Managed Switches clear logging email statisticsThis command resets the email alerting statistics.Format cle

Strona 496

Utility Commands545 ProSafe M4100 and M7100 Managed SwitchesportUse this command to configure the TCP port to use for communication with the SMTP serv

Strona 497

Utility Commands546ProSafe M4100 and M7100 Managed Switches System Utility and Clear CommandsThis section describes the commands you use to help troub

Strona 498

Utility Commands547 ProSafe M4100 and M7100 Managed SwitchesThe following are examples of the CLI command.traceroute Success:(Switch) # traceroute 10.

Strona 499

Utility Commands548ProSafe M4100 and M7100 Managed Switches of the traceroute. This port should be an unused port on the destination system. The range

Strona 500

Utility Commands549 ProSafe M4100 and M7100 Managed Switchesclear countersThis command clears the statistics for a specified <slot/port>, for al

Strona 501 - About PoE

Switching Commands55 ProSafe M4100 and M7100 Managed Switchesno protocol groupThis command removes the <vlanid> from this protocol-based VLAN gr

Strona 502 - PoE Commands

Utility Commands550ProSafe M4100 and M7100 Managed Switches enable passwordThis command prompts you to change the Privileged EXEC password. Passwords

Strona 503

Utility Commands551 ProSafe M4100 and M7100 Managed SwitchesUsing the options described below, you can specify the number and size of Echo Requests an

Strona 504

Utility Commands552ProSafe M4100 and M7100 Managed Switches command, configure the switch for network (in-band) connection. The source and target devi

Strona 505

Utility Commands553 ProSafe M4100 and M7100 Managed SwitchesquitThis command closes the current telnet connection or resets the current serial connect

Strona 506 - Mode Interface Config

Utility Commands554ProSafe M4100 and M7100 Managed Switches In the copy url ias-users command, for url, use one of the following for the IAS user&apos

Strona 507

Utility Commands555 ProSafe M4100 and M7100 Managed Switchesnvram:traplog <url> Copies the trap log file to a server.system:running-config nvram

Strona 508

Utility Commands556ProSafe M4100 and M7100 Managed Switches write memoryUse this command to save running configuration changes to NVRAM so that the ch

Strona 509

Utility Commands557 ProSafe M4100 and M7100 Managed Switchessntp client modeThis command enables Simple Network Time Protocol (SNTP) client mode and m

Strona 510 - PSE-capable ports

Utility Commands558ProSafe M4100 and M7100 Managed Switches no sntp unicast client poll-intervalThis command resets the poll interval for SNTP unicast

Strona 511

Utility Commands559 ProSafe M4100 and M7100 Managed Switchessntp serverThis command configures an SNTP server (a maximum of three). The optional prior

Strona 512 - Utility Commands

Switching Commands56ProSafe M4100 and M7100 Managed Switches no protocol vlan group allThis command removes all interfaces from this protocol-based VL

Strona 513 - Auto Install Commands

Utility Commands560ProSafe M4100 and M7100 Managed Switches clock setThis command sets the system time and date. Format clock set <hh:mm:ss>cloc

Strona 514

Utility Commands561 ProSafe M4100 and M7100 Managed Switches• offset—Number of minutes to add during the summertime. (Range:1-1440)• acronym—T

Strona 515 - Dual Image Commands

Utility Commands562ProSafe M4100 and M7100 Managed Switches show sntp clientThis command is used to display SNTP client settings.Format show sntp clie

Strona 516

Utility Commands563 ProSafe M4100 and M7100 Managed SwitchesFor each configured server: Host AddressAddress TypePriorityVersionPortLast Attempt TimeLa

Strona 517

Utility Commands564ProSafe M4100 and M7100 Managed Switches DHCP Server CommandsThis section describes the commands you to configure the DHCP server s

Strona 518

Utility Commands565 ProSafe M4100 and M7100 Managed Switchesclient-nameThis command specifies the name for a DHCP client. Name is a string consisting

Strona 519

Utility Commands566ProSafe M4100 and M7100 Managed Switches no dns-serverThis command removes the DNS Server list. Format no dns-server Modehardware-a

Strona 520

Utility Commands567 ProSafe M4100 and M7100 Managed SwitchesleaseThis command configures the duration of the lease for an IP address that is assigned

Strona 521

Utility Commands568ProSafe M4100 and M7100 Managed Switches no bootfileThis command deletes the boot image name.Format no bootfileModedomain-nameThis

Strona 522

Utility Commands569 ProSafe M4100 and M7100 Managed Switchesnetbios-node-typeThe command configures the NetBIOS node type for Microsoft Dynamic Host C

Strona 523

Switching Commands57 ProSafe M4100 and M7100 Managed Switchesvlan association subnetThis command associates a VLAN to a specific IP-subnet.Format vlan

Strona 524

Utility Commands570ProSafe M4100 and M7100 Managed Switches period (for example, a3.4f.22.0c), colon (for example, a3:4f:22:0c), or white space (for e

Strona 525

Utility Commands571 ProSafe M4100 and M7100 Managed Switchesno ip dhcp ping packetsThis command prevents the server from pinging pool addresses and se

Strona 526

Utility Commands572ProSafe M4100 and M7100 Managed Switches ip dhcp conflict loggingThis command enables conflict logging on DHCP server.DefaultFormat

Strona 527

Utility Commands573 ProSafe M4100 and M7100 Managed Switchesshow ip dhcp bindingThis command displays address bindings for the specific IP address on

Strona 528

Pool NamePool TypeLease TimeDNS ServersDefault RoutersUtility Commands574ProSafe M4100 and M7100 Managed Switches The following additional field is di

Strona 529

Utility Commands575 ProSafe M4100 and M7100 Managed SwitchesMessage Received:DHCP DISCOVERDHCP REQUESTDHCP DECLINEDHCP RELEASEDHCP INFORMMessage Sent:

Strona 530

Utility Commands576ProSafe M4100 and M7100 Managed Switches ip domain lookupUse this command to enable the DNS client.DefaultFormat ip domain lookupMo

Strona 531

Utility Commands577 ProSafe M4100 and M7100 Managed Switchesname command, is used only when the default domain name list is empty. A maximum of 32 nam

Strona 532

Utility Commands578ProSafe M4100 and M7100 Managed Switches no ip hostUse this command to remove the name-to-address mapping.Format no ip host <nam

Strona 533

Utility Commands579 ProSafe M4100 and M7100 Managed Switchesip domain timeoutUse this command to specify the amount of time to wait for a response to

Strona 534 - Logging Commands

Switching Commands58ProSafe M4100 and M7100 Managed Switches show vlan <vlanid>This command displays detailed information, including interface i

Strona 535

Utility Commands580ProSafe M4100 and M7100 Managed Switches Example: The following shows example CLI display output for the command.<Switch> sho

Strona 536

Utility Commands581 ProSafe M4100 and M7100 Managed Switchespackets are captured and capturing packets is stopped automatically.The packet capture ope

Strona 537

Utility Commands582ProSafe M4100 and M7100 Managed Switches no capture Use this command to reset the capture mode to remote mode.Format no captureMode

Strona 538

Utility Commands583 ProSafe M4100 and M7100 Managed Switchesdisplayed during the capturing session. When capturing is in progress, unsaved, not-yet-di

Strona 539

Utility Commands584ProSafe M4100 and M7100 Managed Switches no debug arpUse this command to disable ARP debug protocol messages.Format no debug arpMod

Strona 540

Utility Commands585 ProSafe M4100 and M7100 Managed Switchesno debug consoleThis command disables the display of “debug” trace output on the login ses

Strona 541

Utility Commands586ProSafe M4100 and M7100 Managed Switches debug dhcp packet Use this command to display “debug” information about DHCPv4 client acti

Strona 542

Utility Commands587 ProSafe M4100 and M7100 Managed Switchesno debug igmpsnooping packetThis command disables tracing of IGMP Snooping packets.Format

Strona 543

Utility Commands588ProSafe M4100 and M7100 Managed Switches no debug igmpsnooping transmitThis command disables tracing of transmitted IGMP snooping p

Strona 544

Utility Commands589 ProSafe M4100 and M7100 Managed Switchesno debug igmpsnooping receiveThis command disables tracing of received IGMP Snooping packe

Strona 545

Switching Commands59 ProSafe M4100 and M7100 Managed Switchesshow vlan briefThis command displays a list of all configured VLANs.Format show vlan brie

Strona 546

Utility Commands590ProSafe M4100 and M7100 Managed Switches no debug ip dvmrp packetUse this command to disable debug tracing of DVMRP packet receptio

Strona 547

Utility Commands591 ProSafe M4100 and M7100 Managed Switchesdebug ip pimdm packetUse this command to trace PIMDM packet reception and transmission. re

Strona 548

Utility Commands592ProSafe M4100 and M7100 Managed Switches no debug ip vrrpUse this command to disable VRRP debug protocol messages.Format no debug i

Strona 549

Utility Commands593 ProSafe M4100 and M7100 Managed Switchesdebug ipv6 mld packetUse this command to trace MLDv6 packet reception and transmission. re

Strona 550

Utility Commands594ProSafe M4100 and M7100 Managed Switches no debug ipv6 pimsm packetUse this command to disable debug tracing of PIMSMv6 packet rece

Strona 551

Utility Commands595 ProSafe M4100 and M7100 Managed Switchesno debug mldsnooping packetUse this command to disable debug tracing of MLD snooping packe

Strona 552

Utility Commands596ProSafe M4100 and M7100 Managed Switches The remaining fields in the trace are specific to the type of OSPF Packet.HELLO packet fie

Strona 553

Utility Commands597 ProSafe M4100 and M7100 Managed SwitchesLS_ACK packet field definitions.Lengthno debug ospf packetThis command disables tracing of

Strona 554

Utility Commands598ProSafe M4100 and M7100 Managed Switches The following parameters are displayed in the trace message:TX/RXIntfSRC_IPDEST_IPTypeno d

Strona 555

Utility Commands599 ProSafe M4100 and M7100 Managed SwitchesThe following parameters are displayed in the trace message:TX/RXIntfSrc_IP Dest_IPRip_Ver

Strona 556

6ProSafe M4100 and M7100 Managed SwitchesSoftware License Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .609IP Address Con

Strona 557

Switching Commands60ProSafe M4100 and M7100 Managed Switches show vlan association subnet This command displays the VLAN associated with a specific co

Strona 558

Utility Commands600ProSafe M4100 and M7100 Managed Switches debug spanning-tree bpduThis command enables tracing of spanning tree BPDUs received and t

Strona 559

Utility Commands601 ProSafe M4100 and M7100 Managed Switchesno debug spanning-tree bpdu receiveThis command disables tracing of received spanning tree

Strona 560

Utility Commands602ProSafe M4100 and M7100 Managed Switches debug udld packetThis command enables debugging on the received and transmitted UDLD PDU’s

Strona 561 - For example:

Utility Commands603 ProSafe M4100 and M7100 Managed Switchesdebug aaa accountingThis command is useful for debugging accounting configuration and func

Strona 562

Utility Commands604ProSafe M4100 and M7100 Managed Switches cablestatusThis command returns the status of the specified port.Format cablestatus <sl

Strona 563 - For each configured server:

Utility Commands605 ProSafe M4100 and M7100 Managed Switchesno sflow receiverUse this command to set the sFlow collector parameters back to the defaul

Strona 564 - DHCP Server Commands

Utility Commands606ProSafe M4100 and M7100 Managed Switches no sflow samplerUse this command to reset the sFlow sampler instance to the default settin

Strona 565

Utility Commands607 ProSafe M4100 and M7100 Managed Switchesshow sflow agentThe sFlow agent collects time-based sampling of network interface statisti

Strona 566

Utility Commands608ProSafe M4100 and M7100 Managed Switches show sflow receiversUse this command to display configuration information related to the s

Strona 567

Utility Commands609 ProSafe M4100 and M7100 Managed SwitchesSoftware License CommandsLicense commands allow you to configure advanced features on some

Strona 568

Switching Commands61 ProSafe M4100 and M7100 Managed Switchesdvlan-tunnel ethertypeThis command configures the ether-type for all interfaces. The ethe

Strona 569

Utility Commands610ProSafe M4100 and M7100 Managed Switches (Managed Switches) #show license featuresThis command displays the features that are licen

Strona 570

Utility Commands611 ProSafe M4100 and M7100 Managed Switchesclear ip address-conflict-detectThis command clears the detected address conflict status i

Strona 571

Utility Commands612ProSafe M4100 and M7100 Managed Switches show llpf interface allUse this command to display the status of LLPF rules configured on

Strona 572

Utility Commands613 ProSafe M4100 and M7100 Managed Switches• Group 9 - EventControls the actions that are taken when an event occurs. RMON events occ

Strona 573

Utility Commands614ProSafe M4100 and M7100 Managed Switches no rmon alarmThis command deletes the rmon alarm entry.Format no rmon alarm <alarm numb

Strona 574

Utility Commands615 ProSafe M4100 and M7100 Managed Switchesno rmon hcalarmThis command deletes the rmon hcalarm entry.Format no rmon hcalarm <alar

Strona 575 - DNS Client Commands

Utility Commands616ProSafe M4100 and M7100 Managed Switches rmon collection historyThis command sets the history control parameters of the RMON histor

Strona 576

Utility Commands617 ProSafe M4100 and M7100 Managed Switchesshow rmon historyThis command displays the specified entry in the RMON history table.Forma

Strona 577

Utility Commands618ProSafe M4100 and M7100 Managed Switches show rmon {hcalarms | hcalarm <alarm index>}This command displays the entries in the

Strona 578

Utility Commands619 ProSafe M4100 and M7100 Managed Switchesudld timeout intervalThis command configures the time interval after which UDLD link is co

Strona 579

Switching Commands62ProSafe M4100 and M7100 Managed Switches no mode dvlan-tunnelThis command is used to disable Double VLAN Tunneling on the specifie

Strona 580 - Packet Capture Commands

Utility Commands620ProSafe M4100 and M7100 Managed Switches show udld This command displays the global settings of UDLD.Format show udldModeAdmin Mode

Strona 581

Utility Commands621 ProSafe M4100 and M7100 Managed Switchesshow usb deviceThis command displays USB flash device details.Format show USB deviceModeDe

Strona 582

FilenameFilesizeTotal SizeBytes UsedBytes FreeUtility Commands622ProSafe M4100 and M7100 Managed Switches Example:(switch) #dir USB:Filename Filesize

Strona 583

6231111. Management CommandsThis chapter describes the management commands available in the managed switch CLI.This chapter contains the following s

Strona 584

Management Commands624ProSafe M4100 and M7100 Managed Switches Configuring the Switch Management CPUTo manage the switch via the web GUI or telnet, an

Strona 585

Management Commands625 ProSafe M4100 and M7100 Managed SwitchesThe following is an example of an ezconfig session.NETGEAR EZ Configuration Utility----

Strona 586

Management Commands626ProSafe M4100 and M7100 Managed Switches Network Interface CommandsThis section describes the commands you use to configure a lo

Strona 587

Management Commands627 ProSafe M4100 and M7100 Managed SwitchesA locally administered address must have bit 6 On (b'1') and bit 7 Off (b&apo

Strona 588

Management Commands628ProSafe M4100 and M7100 Managed Switches the switch's network interface do not affect the configuration of the front panel

Strona 589

Management Commands629 ProSafe M4100 and M7100 Managed SwitchesIPv6 Address/Length is ... 3099::210:18FF:FE82:337/64IPv6 Default

Strona 590

Switching Commands63 ProSafe M4100 and M7100 Managed SwitchesVoice VLAN CommandsThis section describes the commands you use for Voice VLAN. Voice VLAN

Strona 591

Management Commands630ProSafe M4100 and M7100 Managed Switches no serial baudrateUse this command to set the communication rate of the terminal interf

Strona 592

Management Commands631 ProSafe M4100 and M7100 Managed Switchesenable authenticationUse this command in line configuration mode to specify an authenti

Strona 593

Management Commands632ProSafe M4100 and M7100 Managed Switches ip telnet server enableUse this command to enable Telnet connections to the system and

Strona 594

Management Commands633 ProSafe M4100 and M7100 Managed Switchesno transport input telnetUse this command to prevent new Telnet sessions from being est

Strona 595

Management Commands634ProSafe M4100 and M7100 Managed Switches no session-limitUse this command to set the maximum number of simultaneous outbound Tel

Strona 596

Management Commands635 ProSafe M4100 and M7100 Managed Switchestelnetcon timeoutUse this command to set the Telnet connection session timeout value, i

Strona 597

Outbound Telnet Login TimeoutMaximum Number of Outbound Telnet SessionsAllow New Outbound Telnet SessionsManagement Commands636ProSafe M4100 and M7100

Strona 598

Management Commands637 ProSafe M4100 and M7100 Managed Switchesip sshUse this command to enable SSH access to the system. (This command is the short f

Strona 599

Management Commands638ProSafe M4100 and M7100 Managed Switches no sshcon maxsessionsUse this command to set the maximum number of allowed SSH connecti

Strona 600

Management Commands639 ProSafe M4100 and M7100 Managed SwitchesManagement Security CommandsThis section describes commands you use to generate keys an

Strona 601

Switching Commands64ProSafe M4100 and M7100 Managed Switches You can configure Voice VLAN in any of the following ways:vlan-iddot1pnoneuntaggedno voic

Strona 602

Management Commands640ProSafe M4100 and M7100 Managed Switches no crypto key generate rsaUse this command to delete the RSA key files from the device.

Strona 603 - Cable Test Command

Management Commands641 ProSafe M4100 and M7100 Managed Switchesno ip http serverUse this command to disable access to the switch through the Web inter

Strona 604

Management Commands642ProSafe M4100 and M7100 Managed Switches user will be forced to reauthenticate. This timer begins on initiation of the web sessi

Strona 605

Management Commands643 ProSafe M4100 and M7100 Managed Switchesip http session maxsessionsUse this command to limit the number of allowable unsecure H

Strona 606

Management Commands644ProSafe M4100 and M7100 Managed Switches no ip http secure-session maxsessionsUse this command to restore the number of allowabl

Strona 607

Management Commands645 ProSafe M4100 and M7100 Managed Switchesip https authenticationUse this command to specify the authentication methods for http

Strona 608 - [<index>]

Management Commands646ProSafe M4100 and M7100 Managed Switches ip http secure-protocolUse this command to set protocol levels (versions). The protocol

Strona 609 - Software License Commands

Management Commands647 ProSafe M4100 and M7100 Managed SwitchesAccess CommandsUse the commands in this section to close remote connections or to view

Strona 610 - IP Address Conflict Commands

Management Commands648ProSafe M4100 and M7100 Managed Switches usernameUse this command to add a new user to the local user database. The default priv

Strona 611

Management Commands649 ProSafe M4100 and M7100 Managed Switchesusername name nopasswordUse this command to remove an existing user’s password (NULL pa

Strona 612 - RFC 2819

Switching Commands65 ProSafe M4100 and M7100 Managed SwitchesWhen the interface is specified:Voice VLAN Interface ModeVoice VLAN IDVoice VLAN Priority

Strona 613 - RFC 3434

Management Commands650ProSafe M4100 and M7100 Managed Switches username snmpv3 authenticationUse this command to specify the authentication protocol t

Strona 614

Management Commands651 ProSafe M4100 and M7100 Managed Switchesno username snmpv3 encryptionUse this command to set the encryption protocol to none. T

Strona 615

Management Commands652ProSafe M4100 and M7100 Managed Switches show users accounts detailThis command displays the local user status about user accoun

Strona 616

Login TimeUsernameProtocolLocationManagement Commands653 ProSafe M4100 and M7100 Managed Switchespasswords min-lengthUse this command to enforce a min

Strona 617

Management Commands654ProSafe M4100 and M7100 Managed Switches passwords agingUse this command to implement aging on passwords for local users. When a

Strona 618 - UDLD Commands

Management Commands655 ProSafe M4100 and M7100 Managed Switchesno passwords strength-checkUse this command to disable the password strength-check.Form

Strona 619

Management Commands656ProSafe M4100 and M7100 Managed Switches passwords strength minimum numeric-charactersUse this command to enforce a minimum numb

Strona 620 - USB commands

Management Commands657 ProSafe M4100 and M7100 Managed Switchesno passwords strength maximum consecutive-charactersUse this command to reset the maxim

Strona 621

Management Commands658ProSafe M4100 and M7100 Managed Switches passwords strength exclude-keywordUse this command to exclude the specified keyword whi

Strona 622

Management Commands659 ProSafe M4100 and M7100 Managed Switchesshow passwords resultUse this command to display the last password set result informati

Strona 623 - Management Commands

Switching Commands66ProSafe M4100 and M7100 Managed Switches If an interface is configured as a protected port, and you add that interface to a Port C

Strona 624

Management Commands660ProSafe M4100 and M7100 Managed Switches list-name Character string used to name the list of authentication methods activated

Strona 625

Management Commands661 ProSafe M4100 and M7100 Managed SwitchesDefault Uses the listed authentication methods that follow this argument as the defau

Strona 626 - Network Interface Commands

Management Commands662ProSafe M4100 and M7100 Managed Switches specified as an authentication method after radius, no authentication is used if the ra

Strona 627

execcommandsdefaultlist-namestart-stopstop-onlynonemethod (method1/method2…)Management Commands663 ProSafe M4100 and M7100 Managed Switchesno aaa acco

Strona 628 - “Interface Status” as “Up”

Management Commands664ProSafe M4100 and M7100 Managed Switches ip http/https accountingThis command applies user exec accounting list to the line meth

Strona 629 - Console Port Access Commands

Management Commands665 ProSafe M4100 and M7100 Managed SwitchesExample:(switch) #(switch) #show accounting methodsAcct Type Method Name Record

Strona 630

Management Commands666ProSafe M4100 and M7100 Managed Switches no aaa authorizationThis command deletes the authorization method list.Format no aaa au

Strona 631 - Telnet Commands

Management Commands667 ProSafe M4100 and M7100 Managed Switches---------------------------- ------------------------------dfltExecAuthList

Strona 632

Management Commands668ProSafe M4100 and M7100 Managed Switches no domain-name enableThis command disables the domain name functionality. Format no dom

Strona 633

Management Commands669 ProSafe M4100 and M7100 Managed Switchesaaa session-idThis global aaa command specifies whether the same session-id is used for

Strona 634

Switching Commands67 ProSafe M4100 and M7100 Managed Switchesno switchport protected (Interface Config)Use this command to configure a port as unprote

Strona 635

Management Commands670ProSafe M4100 and M7100 Managed Switches clear aaa ias-usersUse this command to remove all users from the IAS database.Format cl

Strona 636 - Secure Shell (SSH) Commands

Management Commands671 ProSafe M4100 and M7100 Managed Switchesno snmp-server community Use this command to remove this community name from the table.

Strona 637

Management Commands672ProSafe M4100 and M7100 Managed Switches station, and will use that machine's IP address for the client IP address. A value

Strona 638

Management Commands673 ProSafe M4100 and M7100 Managed Switchessnmp-server community roUse this command to restrict access to switch information. The

Strona 639 - Management Security Commands

Management Commands674ProSafe M4100 and M7100 Managed Switches no snmp-server enable trapsUse this command to disable the Authentication Flag.Format n

Strona 640

Management Commands675 ProSafe M4100 and M7100 Managed Switchesno snmp-server enable traps multiusersUse this command to disable Multiple User traps.

Strona 641

Management Commands676ProSafe M4100 and M7100 Managed Switches no snmptrap Use this command to delete trap receivers for a community. Format no snmptr

Strona 642

Management Commands677 ProSafe M4100 and M7100 Managed Switchessnmptrap modeUse this command to activate or deactivate an SNMP trap. Enabled trap rece

Strona 643

Management Commands678ProSafe M4100 and M7100 Managed Switches snmp trap link-status allUse this command to enable link status traps for all interface

Strona 644

Management Commands679 ProSafe M4100 and M7100 Managed SwitchesTCP/IP to an external SNMP manager based on the SNMP configuration (the trap receiver a

Strona 645

Switching Commands68ProSafe M4100 and M7100 Managed Switches Private VLANThe Private VLANs feature separates a regular VLAN domain into two or more su

Strona 646

Management Commands680ProSafe M4100 and M7100 Managed Switches Community Name IpAddress IPv6 Address Snmp Version Mode Mytrap

Strona 647 - User Account Commands

Management Commands681 ProSafe M4100 and M7100 Managed Switchesauthorization network radiusUse this command to enable the switch to accept VLAN assign

Strona 648

Management Commands682ProSafe M4100 and M7100 Managed Switches no radius server attributeUse the no version of this command to disable the NAS-IP-Addr

Strona 649

Management Commands683 ProSafe M4100 and M7100 Managed SwitchesNote: To reconfigure a RADIUS accounting server to use the default UDP <port>, s

Strona 650

Management Commands684ProSafe M4100 and M7100 Managed Switches radius server keyUse this command to configure the key to be used in RADIUS client comm

Strona 651

Management Commands685 ProSafe M4100 and M7100 Managed Switchesno radius server msgauthUse the no version of this command to disable the message authe

Strona 652

Management Commands686ProSafe M4100 and M7100 Managed Switches no radius server retransmitUse this command to set the value of this global parameter t

Strona 653

Number of Configured Authentication ServersNumber of Configured Accounting ServersNumber of Named Authentication Server GroupsNumber of Named Accounti

Strona 654

Management Commands688ProSafe M4100 and M7100 Managed Switches The following shows example CLI display output for the command.(Switch) #show radius se

Strona 655

Management Commands689 ProSafe M4100 and M7100 Managed Switches192.168.37.201 Network2_RADIUS_Server Primary192.168.37.202

Strona 656

host-associationmappingprimary-vlan-idsecondary-vlan-idaddremovesecondary-vlan-listSwitching Commands69 ProSafe M4100 and M7100 Managed Switchesno swi

Strona 657

Management Commands690ProSafe M4100 and M7100 Managed Switches The following shows example CLI display output for the command.(Switch) #show radius ac

Strona 658

Management Commands691 ProSafe M4100 and M7100 Managed SwitchesThe following shows example CLI display output for the command.(Switch) #show radius ac

Strona 659

Management Commands692ProSafe M4100 and M7100 Managed Switches Malformed Responses... 0Bad Authenticators...

Strona 660

Management Commands693 ProSafe M4100 and M7100 Managed SwitchesThe following shows example CLI display output for the command.(Switch) #show radius st

Strona 661

Management Commands694ProSafe M4100 and M7100 Managed Switches debug tacacs packetUse the debug tacacs packet command to turn on TACACS+ packet debug.

Strona 662

Management Commands695 ProSafe M4100 and M7100 Managed Switcheskeyword. In the show running config command’s display, these secret keys are displayed

Strona 663

Management Commands696ProSafe M4100 and M7100 Managed Switches no tacacs-server source interfaceUse this command in Global Configuration mode to remov

Strona 664

Management Commands697 ProSafe M4100 and M7100 Managed SwitchesportUse the port command in TACACS Configuration mode to specify a server port number.

Strona 665

Management Commands698ProSafe M4100 and M7100 Managed Switches Configuration Scripting CommandsConfiguration Scripting allows you to generate text-for

Strona 666

Management Commands699 ProSafe M4100 and M7100 Managed Switches " " hello helloscript applyUse this command to apply

Strona 667

711. Using the Command-Line InterfaceThe command-line interface (CLI) is a text-based way to manage and monitor the system. You can access the CLI b

Strona 668

Switching Commands70ProSafe M4100 and M7100 Managed Switches private-vlanThis command is used to configure the private VLANs and to configure the asso

Strona 669

Management Commands700ProSafe M4100 and M7100 Managed Switches script validateUse this command to validate a script file by parsing each line in the s

Strona 670 - SNMP Commands

Management Commands701 ProSafe M4100 and M7100 Managed Switchesset clibannerUse this command to add the CLI Banner. The banner message supports up to

Strona 671

ipv4-routing dual-ipv4-and-ipv6 Management Commands702ProSafe M4100 and M7100 Managed Switches no sdm prefer Use this command to return to the default

Strona 672

Management Commands703 ProSafe M4100 and M7100 Managed SwitchesExample: #show sdm prefer Current template: Dual IPv4 and IPv6ARP Entries...

Strona 673

Management Commands704ProSafe M4100 and M7100 Managed Switches network ipv6 addressUse this command to configure an IPv6 global address, enable or dis

Strona 674

Management Commands705 ProSafe M4100 and M7100 Managed Switchesno network ipv6 gatewayUse this command to remove IPv6 gateways on the network port int

Strona 675

Management Commands706ProSafe M4100 and M7100 Managed Switches The following example shows CLI display output for the command:(switch)#show network ip

Strona 676

Management Commands707 ProSafe M4100 and M7100 Managed Switchesclear network ipv6 dhcp statisticsUse this command to clear the DHCPv6 statistics on th

Strona 677

7081212. Log MessagesThis chapter lists common log messages, along with information regarding the cause of each message. There is no specific action

Strona 678

Log Messages709 ProSafe M4100 and M7100 Managed SwitchesCoreTable 3. BSP Log Messages Component Message CauseBSPEvent(0xaaaaaaaa) Switch has restart

Strona 679

Private -vlantypePrimarySecondaryTypePortsSwitching Commands71 ProSafe M4100 and M7100 Managed Switchesshow interface ethernet <slot/port > swit

Strona 680 - RADIUS Commands

Log Messages710ProSafe M4100 and M7100 Managed Switches Table 5. System Log Messages Component Message CauseSYSTEMConfiguration file Switch CLI.cfg s

Strona 681

Log Messages711 ProSafe M4100 and M7100 Managed SwitchesUtilitiesTable 6. Trap Mgr Log MessageComponent Message CauseTrap MgrLink Up/Down: slot/port

Strona 682

Log Messages712ProSafe M4100 and M7100 Managed Switches Table 9. RADIUS Log Messages Component Message CauseRADIUSRADIUS: Invalid data length - xxx T

Strona 683

Log Messages713 ProSafe M4100 and M7100 Managed SwitchesManagementTable 10. TACACS+ Log Messages Component Message CauseTACACS+TACACS+: authenticatio

Strona 684

Log Messages714ProSafe M4100 and M7100 Managed Switches Table 14. EmWeb Log Messages Component Message CauseEmWebEMWEB (Telnet): Max number of Telnet

Strona 685

Log Messages715 ProSafe M4100 and M7100 Managed SwitchesTable 16. WEB Log MessagesComponent Message CauseWEBMax clients exceeded This message is show

Strona 686

Log Messages716ProSafe M4100 and M7100 Managed Switches SSHDSSHD: Unknown UI event in message, event=XXXXFailed to dispatch the UI event to the approp

Strona 687

Log Messages717 ProSafe M4100 and M7100 Managed SwitchesSwitchingTable 20. User_Manager Log MessagesComponent Message CauseUser_ManagerUser Login Fai

Strona 688

Log Messages718ProSafe M4100 and M7100 Managed Switches Table 22. IP Subnet VLANS Log MessagesComponent Message CauseIPsubnet vlansERROR vlanIpSubnet

Strona 689

Log Messages719 ProSafe M4100 and M7100 Managed SwitchesMac based VLANSvlanMacVlanChangeCallback: Failed to add an entryAppears when a dtl fails to ad

Strona 690

Switching Commands72ProSafe M4100 and M7100 Managed Switches no set garp timer join This command sets the GVRP join time (for one or all ports and per

Strona 691

Log Messages720ProSafe M4100 and M7100 Managed Switches IGMP SnoopingFailed to set igmp mrouter mode %d for interface xxx on VLAN yyyFailed to set VLA

Strona 692

Log Messages721 ProSafe M4100 and M7100 Managed SwitchesTable 27. 802.3ad Log MessagesComponent Message Cause802.3addot3adReceiveMachine: received de

Strona 693 - TACACS+ Commands

Log Messages722ProSafe M4100 and M7100 Managed Switches Table 32. 802.1Q Log MessagesComponent Message Cause802.1Qdot1qIssueCmd: Unable to send messa

Strona 694 - <ip-address

Log Messages723 ProSafe M4100 and M7100 Managed SwitchesQoSTable 35. Protocol-based VLANs Log MessagesComponent Message CauseProtocol Based VLANspbVl

Strona 695

Log Messages724ProSafe M4100 and M7100 Managed Switches Routing/IPv6 RoutingTable 38. DiffServ Log MessagesComponent Message CauseDiffServdiffserv.c

Strona 696

Log Messages725 ProSafe M4100 and M7100 Managed SwitchesOSPFv2Warning: OSPF LSDB is 90% full (22648 LSAs).OSPFv2 limits the number of Link State Adver

Strona 697 - <priority>

Log Messages726ProSafe M4100 and M7100 Managed Switches Table 42. Routing Table Manager Log Messages Component Message CauseRouting Table ManagerRTO

Strona 698

Log Messages727 ProSafe M4100 and M7100 Managed SwitchesMulticastTable 45. RIP Log MessageComponent Message CauseRIPRIP : discard response from xxx v

Strona 699

Log Messages728ProSafe M4100 and M7100 Managed Switches Table 49. IGMP-Proxy Log MessagesComponent Message CauseIGMP-ProxyError getting memory for ig

Strona 700

Log Messages729 ProSafe M4100 and M7100 Managed SwitchesStackingTable 51. PIM-DM Log MessagesComponent Message CausePIM-DMOut of memory when creating

Strona 701

Switching Commands73 ProSafe M4100 and M7100 Managed Switchesno set garp timer leaveallThis command sets how frequently Leave All PDUs are generated t

Strona 702

Log Messages730ProSafe M4100 and M7100 Managed Switches TechnologiesTable 54. System General Error MessagesComponent Message CauseOS Invalid USP unit

Strona 703 - IPv6 Management Commands

Log Messages731 ProSafe M4100 and M7100 Managed SwitchesOS USL: A Trunk being created by bcmx already existed in USLPossible synchronization issue bet

Strona 704

Log Messages732ProSafe M4100 and M7100 Managed Switches O/S SupportOS USL: failed to sync L3 Route table on unit=xCould not synchronize unit x due to

Strona 705

Log Messages733 ProSafe M4100 and M7100 Managed SwitchesOSAPI osapiCleanupIf: NetIPGet During the call to remove the interface from the route table, t

Strona 706

7341313. Green Ethernet CommandsNETGEAR Managed Switch Release 10.0.1 supports the following Green Ethernet power saving modes:• Energy Detect M

Strona 707

Green Ethernet Commands735 ProSafe M4100 and M7100 Managed SwitchesEnergy-Detect ModeWhen Energy-Detect mode is enabled, if communication on a port st

Strona 708 - Log Messages

Green Ethernet Commands736ProSafe M4100 and M7100 Managed Switches green-mode energy-detectUse this command enables energy-detect mode on an interface

Strona 709 - Table 4. NIM Log Messages

Green Ethernet Commands737 ProSafe M4100 and M7100 Managed Switchesclear green-mode statisticsThis command to clears the following for a specified <

Strona 710

Green Ethernet Commands738ProSafe M4100 and M7100 Managed Switches EEEEEE Admin Mode EEE Admin Mode is enabled or disabled.Transmit Idle Time It is th

Strona 711 - Utilities

Green Ethernet Commands739 ProSafe M4100 and M7100 Managed SwitchesNote: Executing 'clear green-mode statistics' only clears the EEE Transm

Strona 712

Switching Commands74ProSafe M4100 and M7100 Managed Switches no set gvrp adminmodeThis command disables GVRP.Format no set gvrp adminmodeModeset gvrp

Strona 713 - Management

Green Ethernet Commands740ProSafe M4100 and M7100 Managed Switches Cumulative Energy Saving (W * H)... XX Time Since Counters L

Strona 714

Green Ethernet Commands741 ProSafe M4100 and M7100 Managed SwitchesExample:The output of 'show green-mode <u/s/p>' is indicated below.

Strona 715 - Table 18. SSHD Log Messages

Green Ethernet Commands742ProSafe M4100 and M7100 Managed Switches Interface Energy-Detect Short-Reach-Config Short-Reach EEE

Strona 716 - Table 19. SSLT Log Messages

Green Ethernet Commands743 ProSafe M4100 and M7100 Managed Switchesshow green-mode eee-lpi-history interface <slot/port>This command displays th

Strona 717 - Switching

7441414. Command Listip vrrp (Global Config) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 718

Command List745 ProSafe M4100 and M7100 Managed Switchesarea virtual-link authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 719

Command List746ProSafe M4100 and M7100 Managed Switches classofservice dot1p-mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 720

Command List747 ProSafe M4100 and M7100 Managed Switchesclear traplog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 721 - Table 31. MFDB Log Message

Command List748ProSafe M4100 and M7100 Managed Switches debug spanning-tree bpdu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 722

Command List749 ProSafe M4100 and M7100 Managed Switchesdos-control tcpoffset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 723 - Table 37. CoS Log Message

Switching Commands75 ProSafe M4100 and M7100 Managed SwitchesGMRP CommandsThis section describes the commands you use to configure and view GARP Multi

Strona 724 - Routing/IPv6 Routing

Command List750ProSafe M4100 and M7100 Managed Switches interface lag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 725

Command List751 ProSafe M4100 and M7100 Managed Switchesip http secure-session soft-timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 726 - Table 44. ARP Log Message

Command List752ProSafe M4100 and M7100 Managed Switches ip pim join-prune-interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 727 - Multicast

Command List753 ProSafe M4100 and M7100 Managed Switchesipv6 mld-proxy unsolicit-rprt-interval . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 728

Command List754ProSafe M4100 and M7100 Managed Switches lacp actor port priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 729 - Stacking

Command List755 ProSafe M4100 and M7100 Managed Switchesmac access-list extended rename . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 730 - Technologies

Command List756ProSafe M4100 and M7100 Managed Switches netbios-node-type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 731

Command List757 ProSafe M4100 and M7100 Managed Switchespasswords strength minimum lowercase-letters . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 732 - O/S Support

Command List758ProSafe M4100 and M7100 Managed Switches protocol vlan group all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 733

Command List759 ProSafe M4100 and M7100 Managed Switchesset gvrp adminmode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 734 - Green Ethernet Commands

Switching Commands76ProSafe M4100 and M7100 Managed Switches set gmrp interfacemodeThis command enables GARP Multicast Registration Protocol on a sing

Strona 735 - Energy-Detect Mode

Command List760ProSafe M4100 and M7100 Managed Switches show dampening interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 736

Command List761 ProSafe M4100 and M7100 Managed Switchesshow ip dhcp global configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 737

Command List762ProSafe M4100 and M7100 Managed Switches show ip pim bsr-router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 738

Command List763 ProSafe M4100 and M7100 Managed Switchesshow ipv6 ospf range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 739

Command List764ProSafe M4100 and M7100 Managed Switches show mac-address-table multicast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 740 - Table 58

Command List765 ProSafe M4100 and M7100 Managed Switchesshow running-config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 741

Command List766ProSafe M4100 and M7100 Managed Switches shutdown all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 742

Command List767 ProSafe M4100 and M7100 Managed Switchessplit-horizon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 743

Command List768ProSafe M4100 and M7100 Managed Switches udld port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 744 - Command List

Switching Commands77 ProSafe M4100 and M7100 Managed Switchesshow mac-address-table gmrpThis command displays the GMRP entries in the Multicast Forwar

Strona 745

Switching Commands78ProSafe M4100 and M7100 Managed Switches clear dot1x statisticsThis command resets the 802.1x statistics for the specified port or

Strona 746

Switching Commands79 ProSafe M4100 and M7100 Managed Switchesno dot1x guest-vlanThis command disables Guest VLAN on the interface.DefaultFormat no dot

Strona 747

Using the Command-Line Interface8ProSafe M4100 and M7100 Managed Switches Licensing and Command SupportAs shown in the following table, some command g

Strona 748

Switching Commands80ProSafe M4100 and M7100 Managed Switches no dot1x max-reqThis command sets the maximum number of times the authenticator state mac

Strona 749

Switching Commands81 ProSafe M4100 and M7100 Managed Switchesno dot1x port-controlThis command sets the 802.1x port control mode on the specified port

Strona 750

Switching Commands82ProSafe M4100 and M7100 Managed Switches no dot1x re-authenticationThis command disables re-authentication of the supplicant for t

Strona 751

Switching Commands83 ProSafe M4100 and M7100 Managed Switchesno dot1x timeoutThis command sets the value, in seconds, of the timer used by the authent

Strona 752

Switching Commands84ProSafe M4100 and M7100 Managed Switches no dot1x unauthenticated-vlanThis command resets the unauthenticated-vlan associated with

Strona 753

Switching Commands85 ProSafe M4100 and M7100 Managed Switchesno dot1x dynamic-vlan enableUse this command to disable the switch from creating VLANs dy

Strona 754

Switching Commands86ProSafe M4100 and M7100 Managed Switches show authentication methodsThis command displays information about the authentication met

Strona 755

Switching Commands87 ProSafe M4100 and M7100 Managed SwitchesIf you do not use the optional parameters <slot/port> or <vlanid>, the comman

Strona 756

Switching Commands88ProSafe M4100 and M7100 Managed Switches Backend Authentication StateCurrent state of the backend authentication state machine. Po

Strona 757

Switching Commands89 ProSafe M4100 and M7100 Managed SwitchesThe show dot1x detail <slot/port> command will display the following MAC-based dot1

Strona 758

Using the Command-Line Interface9 ProSafe M4100 and M7100 Managed SwitchesCommand SyntaxA command is one or more words that might be followed by one o

Strona 759

Switching Commands90ProSafe M4100 and M7100 Managed Switches show dot1x clientsThis command displays 802.1x client information. This command also disp

Strona 760

Switching Commands91 ProSafe M4100 and M7100 Managed Switchesshow dot1x usersThis command displays 802.1x port security user information for locally c

Strona 761

Switching Commands92ProSafe M4100 and M7100 Managed Switches dot1x supplicant port-controlUse this command to set the ports authorization state (Autho

Strona 762

Switching Commands93 ProSafe M4100 and M7100 Managed Switchesdot1x supplicant timeout start-periodUse this command to configure the start period timer

Strona 763

Switching Commands94ProSafe M4100 and M7100 Managed Switches no dot1x supplicant timeout auth-periodUse this command to set the auth-period value to t

Strona 764

Switching Commands95 ProSafe M4100 and M7100 Managed Switchesrate kbps. For example, if the configured limit is 10%, this is converted to ~25000 pps,

Strona 765

Switching Commands96ProSafe M4100 and M7100 Managed Switches no storm-control broadcast levelThis command sets the broadcast storm recovery threshold

Strona 766

Switching Commands97 ProSafe M4100 and M7100 Managed Switchesstorm-control broadcast level (Global)This command configures the broadcast storm recover

Strona 767

Switching Commands98ProSafe M4100 and M7100 Managed Switches storm-control multicastThis command enables multicast storm recovery mode for an interfac

Strona 768

Switching Commands99 ProSafe M4100 and M7100 Managed Switchesthe traffic is dropped. Therefore, the rate of multicast traffic is limited to the config

Komentarze do niniejszej Instrukcji

Brak uwag