7000 Series L3 Managed Switch Reference Manual for Software v2.0
Administration Console Telnet Interface 3-3
4.
When the following screen appears, make sure that the port setting are as follows:
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Figure 3-4: Connection Settings
5.
Click OK.
The Hyper Terminal window will open and you should be connected to the switch. If you do not
get a welcome screen or a system menu, hit the return key.
When attached to the User Interface via a Telnet Session, the following must be set in order to use
the arrow keys: Under the terminal pull down menu choose Properties and make sure the VT100
Arrows option is turned on.
Introduction to the Command Menu Interface
The switch offers a Command Menu Interface (CMI), which is a menu-driven method for
managing the switch, as well as a Command Line Interface (CLI), which uses text inputs to
manage the switch. The CLI is accessed through the CMI, but is not addressed in this chapter.
Chapter 5 discusses the CLI in detail.